3.5
Electrical installation of the
remote control (optional)
The remote control allows to trigger the overspeed
governor electrically in downward direction with
rated or service speed.
Additionally the remote control can be used to
reset the contact plate electrically.
3.5.1
Wiring of the remote control
The overspeed contact and the motor are
pre-wired, adjusted and sealed in the fac-
tory.
Power supply of the motor:
Voltage
24VDC +10/-15%
Current
1,6A +/-10%
switch-on time
min. 2 sec
max.30 sec
Motor protection:
The motor protection (PTC) is included in the con-
nection box of the remote control.
-
response time for the motor protection:
typical 5 sec. max. 30 sec.
-
recovery time for the motor protection:
in. 120 sec.