TwinLock 7220
Version 1.08A
93
Arming Device: TwinAlarm
Power supply:
12 VDC
Current consumption:
Idle state:
approx. 10mA
each active output relay: approx. 20mA
Dimensions:
3.94 x 5.91 x 1.38 inches (L x W x H)
Environment:
32°F - 122°F, 75% RH
Environment class II according to VdS
Protection class: IP 30
Connections.
2 RJ11 connectors for the connection of the system busses A and B
Terminal connectors for the serial interface RS232 (RX, TC and GND, 1200 baud
8N1), power supply (12 VDC), distributor, inputs and outputs.
Bus distributor: TwinConnect
Power Supply
12 VDC (optional)
Current consumption
For power supply operation 12 VDC: Approx. 9 mA
Only as distributor:
0 mA
Dimensions:
3.94 x 2.36 x 0.98 inches (L x W x H)
Environment:
32°F - 122°F, 75% RH
Environment class II according to VdS
Protection class:
IP 30
Extension Unit: TwinXT
Power Supply
12 VDC (optional)
Only for output relay operation
Current consumption
For power supply operation 12 VDC:Approx. 20 mA
Per relay
Only when the inputs are used: 0 mA
Dimensions:
3.94 x 2.36 x 0.98 inches (L x W x H)
Environment:
32°F - 122°F, 75% RH
Environment class II according to VdS
Protection class:
IP 30