TwinLock 7220
Version 1.08A
51
6.10. Program Unlocking Time Delay
Menu Navigation:
Select the menu item ‘
time delay
’
(see menu plan 4.2/ see above)
When several locks are available
in the system, select one lock.
Enter the master code of the
selected lock
Evaluate the entry
Display current settings
Start the entry with ENTER.
Enter the new end time
Action completed
Automatic return after 3 seconds
Time Delay for Unlocking:
This function delays the unlocking procedure when the code is entered correctly. The
time is entered in minutes (00-99). A time delay can be entered for each lock.
Release time:
The release time is used to safeguard the time delay. If a release time was
programmed (e.g. >00), a correct unlocking code must be entered after the time
delay has expired, to finally open the lock.
The release time is set in minutes (00-99) and specifies the period, during which the
user can re-enter the unlocking code after the time delay has expired. If no release
was programmed (00), the lock will open without re-entering the code after the time
delay has expired.
The programming of this function can only be performed by the owner of the system
code and is saved in the event log!
Factory setting:
Time: 00 Rel.: 00 (deactivated)
lock
time delay
time delay
lock 01
Master code
Please wait
time delay
Time:00 Rel.:00
time delay
Time:04 Rel.:05
time delay
saved
time delay
deleted
*** TwinLock ***
21.05.09 12:00
*** TwinLock ***
Configuration
Configuration
Lock
Lock
Time delay
Master code
Code:********