21
21
REPLACEMENT OF THE
INJECTORS
If the injectors are not supplied they
can be obtained from the “Service
Centre”.
Select the injectors to be replaced
according to the “Table for the choice of
the injectors”.
The nozzle diameters, expressed in
hundredths of a millimetre, are marked on
the body of each injector.
REPLACEMENT OF THE
INJECTORS OF THE COOKTOP
BURNERS
To replace the injectors proceed as
follows:
•
Remove pan supports and burners
from the cooktop.
•
Using a wrench, substitute the nozzle
injectors “
J
” (figs. 2.3, 2.4) with those
most suitable for the kind of gas for
which it is to be used.
The burners are conceived in such a
way so as not to require the regulation
of the primary air.
ADJUSTING OF THE MINIMUM OF
THE TOP BURNERS
In the minimum position the flame must
have a length of about 4 mm and must
remain lit even with a quick turn from the
maximum position to that of minimum.
The flame adjustment is done in the
following way:
•
Turn on the burner.
•
Turn the tap to the MINIMUM position.
•
Take off the knob.
•
With a thin screwdriver turn the screw
“
A
” until adjustment is correct (fig. 2.5).
Normally for G30/G31 (LPG), the
regulation screw is tightened up.
Double-ring compact
burner
J
fig. 2.3
fig. 2.5
A
fig. 2.4
J
Auxiliary,
Semi-rapid and
Rapid burners
Summary of Contents for 24310037
Page 1: ...DUAL FUEL COOKERS WGC906 Installation advices Instructions for the use FI SE DK NO...
Page 2: ...2 2...
Page 24: ...24 24...
Page 25: ...25 25 Advice for the users...
Page 44: ...44 44 A B T S Fig 6 4 Fig 6 3 Fig 6 5 Fig 6 1 Fig 6 2 S F C T...
Page 49: ...49 49...
Page 50: ...50 50...
Page 51: ...51 51...