The installation conditions, concerning protection against overheating of the surfaces
adjacent to the cooker, must conform to figs. 1.1a or 1.1b.
The cooker must be kept no less than 200 mm away from any side wall which exceed the
height of the cooktop.
The veneered syntetical material and the glue used must be resistant to a temperature of
150°C in order to avoid ungluing or deformations.
Curtains must not be fitted immediatly behind appliance or within 500 mm of the sides.
If the cooker is located on a pedestal it is necessary to provide safety measures to
prevent falling out.
The appliance must be
housed in heat resistant
units.
The walls of the units must
not be higher than work
top and must be capable of
resisting temperatures of
70 °C
above room temperature.
Do not instal the appliance
near inflammable materials
(eg. curtains).
■
Class 1
(fig. 1.1a)
Gas connection made using
rubber hose which must be
visible and easily inspected
or using rigid or flexible metal
pipe.
A space of at least 2 cm must
be left between the cooker and
any adjacent furniture, which
must not exceed the height of
the cooktop.
■
Class 2
■
Subclass 1
(fig. 1.1b)
Gas connection made using
rigid or flexible metal pipe.
650 mm
450 mm
200 mm
500 mm
Fig. 1.1b
450 mm
20 mm
20 mm
650 mm
500 mm
200 mm
Fig. 1.1a
INSTALLATION
1
Summary of Contents for 24310037
Page 1: ...DUAL FUEL COOKERS WGC906 Installation advices Instructions for the use FI SE DK NO...
Page 2: ...2 2...
Page 24: ...24 24...
Page 25: ...25 25 Advice for the users...
Page 44: ...44 44 A B T S Fig 6 4 Fig 6 3 Fig 6 5 Fig 6 1 Fig 6 2 S F C T...
Page 49: ...49 49...
Page 50: ...50 50...
Page 51: ...51 51...