101
WPS-100-DVR-8CH Installation and Users Manual
© 2012 Wirepath Surveillance
• DURATION
Set the duration that the Alarm Out relay and the buzzer will remain triggered when the corresponding
partition is full. Set the time from 3 seconds to 60 minutes or ‘-‘ indefinitely until the Alarm Reset button
on the remote control is pressed.
• ALARM OUT
Define which Alarm Output will be triggered when the corresponding partition is full.
• BUZZER
By default, the internal buzzer is enabled to sound when the corresponding hard drive partition is full.
• LOG
By default, the DVR will log when the corresponding hard drive partition is full to the event Log
Send an e-mail message to a predefined email address when the corresponding hard drive partition is full.
9.4 DUAL STREAMING
This DVR offers two simultaneous video (and audio) streams to allow the DVR to record at a higher resolution
while streaming the video to remote devices at a lower resolution. Dual Streaming can be set two ways.
The first option is to set Compression (found in the Pre-Camera tab) to High. The second option is to set Video
Stream (found in the Network tab) to one of the four QCIF levels.
Recommendation:Set Compression to Normal and use the Video Stream in the Network tab to enable
Dual Streaming.
Internet Explorer allows the user to choose which stream is being viewed, Record or Extra. Use the Modify menu
of Device Config to change the video stream being displayed in Internet Explorer. The setting should be based
on the bandwidth capability of the network.
To access this menu,
select Device Config
icon from Internet Explorer.
1. Select the DVR to control and click on Modify.