TextAlert
IV
User Manual
6.1
Connector Block
Use the orange connector block to wire siren, external speaker, relay contacts and other
wired input devices (e.g. wired PIR or magnetic door contacts).
Gnd –
Ground (0Volts) terminal.
S+Ve –
Siren positive terminal. Connect positive terminal of siren to S+Ve and the
negative terminal of siren to Gnd.
R1 –
potential free terminal 1 of the internal relay (See section 11.6 for configuration of
relay).
R2 –
potential free terminal 2 of the internal relay (See section 11.6 for configuration of
relay).
In 1 – 5
– The wired inputs for wiring external devices onto TA
IV
. If the inputs have been
configured for negative trip (NO), grounding an input onto
Gnd
will trigger the zone
associated with that input. If the inputs have been set up for positive trip (NC), removing
the contact from
Gnd
will trigger the zone associated with that input (Please refer to
Section 9.4).
6.2
Push Button Switches
The record push button switch allows for a 10 second voice message to be recorded onto
the TA
IV
. This voice message will be played back to phone recipient during alarm phone
call.
The reset push button switch is used for programming sensors onto the TA
IV
and for
resting the TA
IV
to factory configuration.
7 Booting Procedure
For first time use:
Please perform a factory reset before continuing. Press and hold in the
RESET button. Turn on the device using the on/off switch. After two seconds, the Status
LED will illuminate red to indicate factory reset. Turn off the device and proceed further as
below.
Turn on the TA
IV
using the on/off switch (make sure that the power adapter is plugged in
so that the internal battery inside the TA
IV
can start to charge up).
The TA
IV
should boot within 3 minutes (average time for boot-up is about 30 seconds).
When the TA
IV
has booted successfully, the Signal LED will flash once a second. If the
Signal LED flashes rapidly or does not flash at all, then please relocate the unit to a new
position with better cell phone reception. A high gain GSM antenna may also be required
to improve GSM signal reception (contact your WirelessAlert agent for details).
7.1
Booting Failure - Troubleshooting
In the event that TA
IV
fails to boot after 3 minutes (Status LED Flashing ‘Orange’
continuously and signal LED not flashing):
•
Verify that the SIM Card does not have a PIN request enabled.
Copyright InFocus Trading 111 cc, 2009