1125100
WPC 1000 User Manual
4-18
Operation
Multiple Operator Stations
If you have wired a single Operator Station to your WPC 1000 and option switch 5 is set to
OFF (see page 3-30), the palm switches on that Operator Station must be pressed within a 1/2-
second “palm time” window (“synchronous” time in ANSI terminology) in order to stroke the
press.
If you have installed multiple Operator Stations (see page 2-17), you must set option switch 5
to ON to establish a 5-second concurrent time for those Op. Stations. Each pair of palm
switches on all connected Operator Stations must be pressed within this 5-second window or
the press will not start. In addition, all Operator Stations must contain a Two-hand Control
module to provide the required 1/2-second palm (or synchronous) time.
HAZARDS EXPOSED BY NON-WORKING OPERATOR STATION
• Safeguard the point of operation exposed by the non-working Operator Station when using
multiple operator stations. The exposed area near a disabled Operator Station must be properly
guarded.
• Ensure that guarding is properly installed to prevent access to the machine over, under or
around any guarding device.
Failure to comply with these instructions will result in death or serious injury.
Do not attempt to install multiple Operator Stations until you have contacted Wintriss Tech.
Support. All Operator Stations in a mutli-Op.-Station configuration must contain a Two-hand
Control module.
DANGER
!
NOTICE
Summary of Contents for WPC 1000
Page 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Page 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Page 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ......
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......