WPC 1000 User Manual
1125100
Initialization, Setup, and Checkout
3-5
When you use this procedure to zero the resolver, WPC 1000 electronically adds or
subtracts any offset between the resolver and the crankshaft, so the resolver always knows
the true zero position of the ram. After zeroing, if the press is at TDC, the crank angle
value in the LED display should read 0°. If it does not, repeat the zeroing process.
Initializing Only the Start-time Limit
If you want to re-initialize only the Start-time Limit without re-initializing the Stop-time
Limit and Resolver Zero settings (see Initializing the System, page 3-3), do the following:
1.
Power down WPC 1000.
2.
While powering WPC 1000 back up, turn the WPC Settings key switch to “–” (i.e.,
clockwise) and hold it there. When “Str” appears in the LED display (see Figure 3-4,
page 3-6), release the key.
Figure 3-3. WPC 1000 Displays Showing “Resolver Zeroed” (“rES”) Message
The Start-time Limit value cannot be changed manually.
BRAKE WARNING
INTERRUPTED STROKE
TOP STOP ANGLE
AUTO CARRYUP
STOP TIME LIMIT
MICRO-INCH
STOPPING TIME
STOPPING ANGLE
90
°
STOP TEST
COUNTER
COUNTER PRESET
ANGLE / SPM
INTERRUPTED STROKE
BRAKE WARNING
TOP STOP ANGLE
AUTO CARRYUP
ANGLE / SPM
90
°
STOP TEST
STOP TIME LIMIT
MICRO-INCH
STOPPING TIME
STOPPING ANGLE
WPC 1000 Standard DisplayWPC 1000 Optional Counter Display
CAM 2
off
on
CAM 1
on
off
Resolver Zeroed message
NOTICE
Summary of Contents for WPC 1000
Page 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Page 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Page 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ......
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......