1125100
WPC 1000 User Manual
A-6
Extracts from OSHA and ANSI
Extracts from ANSI B11.1-2009 8.6.2.1
Standards Requirements
Explanatory Information
8.6.2.1.7 Each operator’s hand controls shall be
located at a distance from the point-of-operation
so that the operator(s) cannot release either
hand actuating control and reach into the point-
of-operation during the hazardous portion of the
cycle.
E8.6.2.1.7 The total stopping time of the press
should include the total response time of the
control system and the time it takes hazardous
motion to stop. The following formula should be
used when calculating the safety distance (Ds):
Ds = K (Ts + Tc + Tbm)
Where:
K = 63 inches/second (hand speed constant).
Ts = the stop time of the press measured from
the final de-energized control element, usually
the air valve.
Tc = the response time of the control.
Tbm = the additional time allowed by the
stopping-performance monitor (brake monitor)
before it detects stop time deterioration.
NOTE – Ts + Tc are usually measured by a stop
time measuring device.
When the press stopping-performance monitor
setting is changed, the safety distance should
be recalculated. See also Annex C.
Summary of Contents for WPC 1000
Page 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Page 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Page 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ......
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......