WPC 1000 User Manual
1125100
Initialization, Setup, and Checkout
3-33
Setting Programmable Cams
If you have ordered the optional two-channel programmable cam output, you can set cam
“on” and “off” angles via the WPC 1000 display. Before making settings, verify that the cam
outputs have been installed correctly (Installing 2-channel Programmable Cam, page 2-34).
The indicator segments used to program cam “on” and “off” angles are labelled on the
standard WPC 1000 display but are not identified on the optional counter display. When
option switch 6 is set to ON, the four segments in the lower half of the display (labelled “Top
Stop Angle,” “Auto Carry-up,” “Stop Time Limit,” and “Micro-inch”) function as indicators
for cam channel settings. The cam channel and state (i.e., ON or OFF) assigned to each
segment is shown for both standard and optional counter displays in Figure 3-12.
To make cam channel settings, perform the following steps:
1.
Set option switch 6 on S101 on the WPC 1000 Control board to ON to enable changes to
cam settings (refer to Switch 6 – Enabling Access to Cam Settings, page 3-30).
2.
Power down the WPC 1000, then power the unit back up to enable the new setting. If you
do not cycle power, the previous switch 6 setting will remain in effect.
3.
Turn the Stroke Select switch to “INCH” to put the press in Inch mode.
4.
Press the Reset/Select button repeatedly until the “Top Stop Angle” segment is
illuminated. When option switch 6 is set to ON, this indicator is used to set the Cam 1
“on” angle.
Figure 3-12. WPC 1000 Displays Showing Cam Indicator Segments
Cam settings cannot be made while the press is running.
WPC 1000 Standard Display
WPC 1000 Optional
Counter Display
INTERRUPTED STROKE
BRAKE WARNING
TOP STOP ANGLE
AUTO CARRYUP
ANGLE / SPM
90
°
STOP TEST
STOP TIME LIMIT
MICRO-INCH
STOPPING TIME
STOPPING ANGLE
BRAKE WARNING
INTERRUPTED STROKE
TOP STOP ANGLE
AUTO CARRYUP
STOP TIME LIMIT
MICRO-INCH
STOPPING TIME
STOPPING ANGLE
90
°
STOP TEST
COUNTER
COUNTER PRESET
ANGLE / SPM
CAM 1
off
on
CAM 2
off
on
When option switch 6 is set to ON,
the four indicator segments in the
the lower half of the display
allow you to set ON and
OFF angles for cam
channels 1 and 2.
Cam 1 ON
Cam 2 ON
Cam 1 OFF
Cam 2 OFF
Cam 1 ON
Cam 2 ON
Cam 1 OFF
Cam 2 OFF
NOTICE
Summary of Contents for WPC 1000
Page 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Page 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Page 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ......
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......