Initialization, Setup, and Checkout
Switch 5 – Selecting Concurrent Time for Multiple Op. Stations
Option switch 5 allows you to select a 5-second concurrent time for WPC 1000 configurations
with two or more Operator Stations installed, as shown in Table 3-9.
Concurrent time is the 5-second interval within which each pair of palm switches on all
connected Operator Stations must be activated in order to start the press. If the concurrent
time is exceeded, the press will not start.
When switch 5 is set to OFF, its default position, and one Operator Station is connected to
WPC 1000, the palm switches on that Operator Station must be pressed within a 1/2-second
window (called the “palm” or “synchronous” time) in order to stroke the press.
When switch 5 is set to ON and two or more Operator Stations are connected to WPC 1000,
palm switches on all connected Operator Stations must be pressed within a 5-second
concurrent time window to start the press. Each Operator Station must contain a Two-hand
Control module to provide the required 1/2-second palm (or synchronous) time.
Switch 6 – Enabling Access to Cam Settings
Switch 6 controls access to settings for cam “on” and “off” angles if you have ordered the
optional two-channel cam output assembly. See Table 3-10, page 3-31.
When switch 6 is set to OFF, cam “on” and “off” angles cannot be set or adjusted. When
switch 6 is set to ON, cam “on”/“off” settings can be made and changed.
You should only change this switch from its default setting if you have installed two or more
Operator Stations on your WPC 1000. Contact Wintriss Tech. Support for further information.
Do not attempt to install multiple Operator Stations until you have contacted Wintriss Tech.
Support. All Operator Stations in a mutli-Op.-Station configuration must contain a Two-hand
Control module. Do not order standard Wintriss “Multiple Operator Stations.”
Table 3-9. Switch 5 Settings: Selecting Concurrent Time for Multiple Operator Stations
Setting
Concurrent Time for Multiple Op. Stations
OFF
Normal Operation (Default). Establishes a 1/2-second palm (or synchronous)
time for one Operator Station.
ON
Establishes a concurrent time of 5 seconds when two or more Operator
Stations are connected to WPC 1000. Each Operator Station must contain a
Two-hand Control module to provide the required 1/2-second palm (or
synchronous) time.
NOTICE
NOTICE
Summary of Contents for WPC 1000
Page 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Page 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Page 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ......
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......