![WinGD X92DF Operation Manual Download Page 57](http://html1.mh-extra.com/html/wingd/x92df/x92df_operation-manual_986583057.webp)
PROCEDURE
1
If an oil mist detector activates an alarm, do as follows:
1.1
Decrease immediately the engine speed (power).
1.2
Stop the engine if possible.
1.3
Let the engine temperature decrease for a minimum of 20 minutes.
1.4
Find the cause and repair the fault.
NOTE:
If no fire-extinguishing system is installed or not in use, a portable fire
extinguisher must be kept ready when the crankcase doors are
opened.
CLOSE UP
•
None
X92DF
AA00-0000-00AAA-012D-A
Operation Manual
Prevent explosions in the crankcase
Winterthur Gas & Diesel Ltd.
- 57 -
Issue 002 2020-08