4.15.2.5
HP SCR system - at engine stop
If you stop the engine in Tier III mode, the HP SCR system changes to bypass mode after some
time. Related to the condition the venting/sealing unit starts for some minutes, refer to
.
4.15.2.6
HP SCR system - cut out
If necessary you can cut out the HP SCR system. When the engine is stopped, you can install
covers to the valves V1 and V2 to make a safe stop of the exhaust gas through the HP SCR
system, refer to section
[section not applicable for this engine]
.
4.15.3
HP SCR control system
The HP SCR control system has the three control boxes that follow:
•
Control box E48
•
Control box E49
•
Control box E50
Each control box is connected through bus connections or hard-wired connections. The control
box E48 is connected to the engine control system (ECS) and to the external HP SCR system
control through bus connections or hard-wired connections, refer to
.
Fig 4-33
HP SCR system - principal control configuration
E49
PCS
ECR
Engine room
E50
E48
AMS
ECS
Signals
External main
control panel
X92DF
AA00-9270-00AAA-043A-A
Operation Manual
HP Selective catalytic reduction system
Winterthur Gas & Diesel Ltd.
- 129 -
Issue 002 2020-08