Control air system
Make sure that the quality of the control air obeys the related specifications in section
Make sure that control air is available at the engine connection 49 (control air supply
inlet).
Make sure that the control air system is full.
•
Fuel system
Make sure that the quality of the fuel obeys the related specifications.
Make sure that fuel is available at the engine connection 45 (fuel inlet).
Make sure that the fuel system is full and the fuel can flow.
•
Exhaust gas system
Make sure that the exhaust gas system is ready for operation.
•
Power supply system
Make sure that the power supply system is ready for operation.
•
Leakage drain system
Make sure that the leakage drain tanks of the plant have sufficient capacity.
For a DF engine, also the systems that follow must be prepared for operation:
•
Gas system
Make sure that the quality of the gas obeys the related specifications in section
.
Make sure that gas is available at the engine connection 78 (gas supply inlet).
•
Pilot fuel system
Make sure that the quality of the pilot fuel obeys the related specifications.
Make sure that pilot fuel is available at the engine connection 76 (supply unit fuel pilot
valve inlet).
Make sure that the pilot fuel system is full and the pilot fuel can flow.
NOTE:
You can start a DF engine only in diesel mode.
8.1.2
Preparation if components are defective
You also can operate the engine, if components of the engine are defective and you cannot
repair the fault immediately. You have to do more preparations related to the defective
component, refer to chapter 10 Troubleshooting.
Obey the limits of operation, if components of the engine are not in operation, refer to section
8.3 Start the engine - general
.
X92DF
AA00-0000-00AAA-120A-A
Operation Manual
Prepare the engine before start - general
Winterthur Gas & Diesel Ltd.
- 429 -