6.9.5
MCP page - GAS SYSTEM
Fig 6-58
MCP page - GAS SYSTEM
001
002
003
Tab 6-44
GAS SYSTEM
Item
Function
Effect
001
FAIL RESET button
Resets a failure that occurred during gas preparation
NOTE:
Use this button only when you have done the related
measures to repair the failure.
002
REQUEST VENTILATION button
Sends a signal for ventilation request
003
CANCEL VENTILATION button
WARNING
Explosion hazard. Cancel the exhaust ventilation only in
an urgent situation. Gas could stay on the engine side, if
the exhaust ventilation is not sufficient.
Stops the exhaust ventilation
X92DF
AA00-4618-07AAA-043B-A
Operation Manual
MCP page - GAS SYSTEM
Winterthur Gas & Diesel Ltd.
- 394 -
Issue 002 2020-08