![WinGD X72-B Operation Manual Download Page 102](http://html1.mh-extra.com/html/wingd/x72-b/x72-b_operation-manual_986578102.webp)
Fig 4-13
HP SCR system - emergency bypass
V1
V2
V3
V7
V4
003
001
007
006
005
004
002
Legend
001
Mixing duct
005
Venting/sealing unit
002
Reactor
006
Urea solution supply unit
003
Turbine of turbocharger
007
Soot blowing unit
004
Engine
X72-B
AA00-9270-00AAA-043A-A
Operation Manual
HP Selective catalytic reduction system
Winterthur Gas & Diesel Ltd.
- 102 -
Issue 003 2021-12