4.12.2 Starting Air Shut-off Valve
1) Remove the shuttle valve 115HA from valve unit
E
. Make sure that the three
O-rings stay in position.
2) On the WECS
−
9520 manual control panel, select LOCAL MANUAL CONTROL
) to get control.
3) Push the button AIR RUN.
4) Make sure that the two solenoid valves ZV7013C and ZV7014C are energized
(use a screwdriver or a magnet tester).
5) Make sure that control air comes out of each pipe from the solenoid valves
ZV7013C and ZV7014C in valve unit
E
(see
6) Make sure that:
D
The shut-off valve for starting air 2.03 is manually closed.
D
There are no active shut-down signals released.
D
The turning gear is disengaged.
D
The auxiliary blowers are set to off (AUX. BLOWER STOP button).
7) On the WECS
−
9520 manual control panel, select START AHEAD.
8) Make sure that the indications No Aux. Blower Running and Start Interlock are
shown on the WECS
−
9520 manual control panel. No start command is released.
9) Select START ASTERN.
10) Make sure that the indications No Aux. Blower Running and Start Interlock are
shown on the WECS
−
9520 manual control panel. No start command is released.
11) Select AUX. BLOWER PRESEL.
12) Do the tests for START AHEAD and START ASTERN as given above.
The auxiliary blowers start and control air comes out of each pipe from the solenoid
valves ZV7013C and ZV7014C in valve unit
E
.
13) Make sure that the O-rings are in position in the shuttle valve 115HA.
14) Install the shuttle valve 115HA to valve unit
E
.
4.12.3 Turning Gear Interlocks
1) Make sure that the turning gear is engaged.
2) Make sure that the pressure switch PS5017C (set
−
point 2 bar) and the switch
ZS5016C are not activated (open contact).
3) Make sure that the indication Turning Gear Engaged is shown on each
WECS
−
9520 manual control panel (i.e. on the ECR console and the local
maneuvering stand.
4) Make sure that the engine is ready for service, the shut-off valve for starting
air 2.03 is closed and the starting air supply pipes have no pressure.
5) On the WECS
−
9520 manual control panel, push the button LOCAL MANUAL
CONTROL (see
6) Push the button START AHEAD.
7) Make sure that Start Interlock is shown on each WECS
−
9520 manual control
panel. No start command is released.
8) Do the test from the ECR manual control panel and the remote control.
9) Disengage the turning gear.
10) Make sure that Start Interlock disappears from each WECS
−
9520 manual control
panel. The Start command is cancelled in the remote control.
2017
−
08
Engine Control
Summary of Contents for W-X82
Page 10: ...Intentionally blank...
Page 14: ...Intentionally blank...
Page 18: ...Intentionally blank...
Page 28: ...Intentionally blank...
Page 34: ...Intentionally blank...
Page 38: ...Intentionally blank...
Page 44: ...Intentionally blank...
Page 52: ...Intentionally blank...
Page 58: ...Intentionally blank...
Page 60: ...Intentionally blank...
Page 62: ...Intentionally blank...
Page 68: ...Intentionally blank...
Page 70: ...Intentionally blank...
Page 76: ...Intentionally blank...
Page 78: ...Intentionally blank...
Page 86: ...Intentionally blank...
Page 92: ...Intentionally blank...
Page 94: ...Intentionally blank...
Page 96: ...Intentionally blank...
Page 100: ...Intentionally blank...
Page 104: ...Intentionally blank...
Page 108: ...Intentionally blank...
Page 112: ...Intentionally blank...
Page 114: ...Intentionally blank...
Page 116: ...Intentionally blank...
Page 138: ...Intentionally blank...
Page 140: ...Intentionally blank...
Page 142: ...Intentionally blank...
Page 144: ...Intentionally blank...
Page 146: ...Intentionally blank...
Page 150: ...Intentionally blank...
Page 154: ...Intentionally blank...
Page 172: ...Intentionally blank...
Page 174: ...Intentionally blank...
Page 208: ...Intentionally blank...
Page 210: ...Intentionally blank...
Page 250: ...Intentionally blank...
Page 252: ...Intentionally blank...
Page 254: ...Intentionally blank...
Page 258: ...Intentionally blank...
Page 262: ...Intentionally blank...
Page 272: ...Intentionally blank...
Page 282: ...Intentionally blank...
Page 286: ...Intentionally blank...
Page 294: ...Intentionally blank...
Page 310: ...Intentionally blank...
Page 332: ...Intentionally blank...
Page 334: ...Intentionally blank...
Page 337: ...Operation 4003 3 A1 Winterthur Gas Diesel Ltd 3 21 WCH00345 2014 Air Supply...
Page 340: ...Operation 4003 3 A1 Winterthur Gas Diesel Ltd 6 21 WCH01167 2014 Servo Oil Supply 9 cylinders...
Page 342: ...Operation 4003 3 A1 Winterthur Gas Diesel Ltd 8 21 WCH01123 2014 Fuel Supply 9 cylinders...
Page 343: ...Operation 4003 3 A1 Winterthur Gas Diesel Ltd 9 21 016 805 08 2014 Starting System...
Page 344: ...Operation 4003 3 A1 Winterthur Gas Diesel Ltd 10 21 016 335 07 2014 Speed Control...
Page 354: ...Operation 4003 3 A1 Winterthur Gas Diesel Ltd 20 21 018 138 09 2014 Cooling Water...
Page 356: ...Intentionally blank...
Page 360: ...Intentionally blank...
Page 366: ...Intentionally blank...
Page 372: ...Intentionally blank...
Page 376: ...Intentionally blank...
Page 380: ...Intentionally blank...
Page 386: ...Intentionally blank...
Page 390: ...Intentionally blank...
Page 400: ...Intentionally blank...
Page 404: ...Intentionally blank...
Page 408: ...Intentionally blank...
Page 416: ...Intentionally blank...
Page 422: ...Intentionally blank...
Page 442: ...Intentionally blank...
Page 450: ...Intentionally blank...
Page 452: ...Intentionally blank...
Page 478: ...Intentionally blank...
Page 484: ...Intentionally blank...
Page 510: ...Intentionally blank...
Page 516: ...Intentionally blank...
Page 520: ...Intentionally blank...
Page 522: ...Intentionally blank...
Page 526: ...Intentionally blank...
Page 542: ...Intentionally blank...
Page 546: ...Intentionally blank...