background image

3

OPM-109

REV B

 

A. Operate only in well ventilated areas.

 

B. Never operate indoors including attached garages

 

C. Never operate the unit in such a way as to allow exhaust gases  

 

  to seep back into closed rooms (i.e. through windows, walls, 

 ÀRRUV

4. NOISE HAZARD - 
Excessive noise is not only tiring, but continual exposure can lead to 
loss of hearing.

 

A. Use hearing protection when working around this equipment for 

 

  long periods of time.

 

B. Keep your neighbors in mind when using this equipment.

5. CLEANLINESS - 
Keep the generator and surrounding area clean.

 

A. Remove all grease, ice, snow or materials that create 

 

  slippery conditions around the unit.

 

B. Remove any rags or other materials that could create a  

 SRWHQWLDO¿UHKD]DUG

 

C. Carefully clean up any gas or oil spills before starting the unit.

6. SERVICING EQUIPMENT -
All service, including the installation or replacement of service parts, 

VKRXOGEHSHUIRUPHGRQO\E\DTXDOL¿HGWHFKQLFLDQ

 

A. Use only factory approved repair parts.

 

B. Do not work on this equipment when fatigued.

 

C. Never remove the protective guards, covers, or receptacle 

 

  panels while the engine is running.

 

D. Use extreme caution when working on electrical components. 

 

  High output voltage from this equipment can cause serious 

 

  injury or death.

($OZD\VDYRLGKRWPXIÀHUVH[KDXVWPDQLIROGVDQGHQJLQHSDUWV

 

  They can cause severe burns instantly.

 

F. The use of the engine-generator set must comply with all  

 

  national, state, and local codes.

SAFETY INFORMATION

This engine generator set has been designed and manufactured to 
allow safe, reliable performance. Poor maintenance, improper or 

FDUHOHVVXVHFDQUHVXOWLQSRWHQWLDOO\GHDGO\KD]DUGVIURPHOHFWULFDO
VKRFNH[KDXVWJDVDVSK\[LDWLRQRU¿UH3OHDVHUHDGDOOVDIHW\

instructions carefully before installation or use. Keep these instructions 
handy for future reference. Take special note and follow all warnings on 
the unit labels and in the manuals.

ANSI SAFETY DEFINITIONS

DANGER:
DANGER indicates an imminently hazardous situation which, if not 
avoided, will result in death or serious injury. This signal word is to be 
limited to the most extreme situations.

WARNING:
WARNING indicates a potentially hazardous situation which, if not 
avoided, could result in death or serious injury.

CAUTION:
CAUTION indicates a potentially hazardous situation which, if not 
avoided, may result in minor or moderate injury. It may also be used to 
alert against unsafe practices.

1. ELECTRICAL SHOCK -
The output voltage present in this equipment can cause fatal electric 
shock. This equipment must be operated by a responsible person.

 

A. Do not allow anyone to operate the generator without proper 

   instruction.
 

B. Guard against electric shock.

 

C. Avoid contact with live terminals or receptacles.

 

D. Use extreme care if operating this unit in rain or snow.

 

E. Use only three-pronged grounded receptacles

 

  and extension cords.

 

F. Be sure the unit is properly grounded to an

 

  external ground rod driven into the earth.

2. FIRE HAZARD - 

*DVROLQHDQGRWKHUIXHOVSUHVHQWDKD]DUGRISRVVLEOHH[SORVLRQDQG
RU¿UH

 
 

A. Do not refuel when the engine is running or hot.

 

B. Keep fuel containers out of reach of children.

&'RQRWVPRNHRUXVHRSHQÀDPHQHDUWKHJHQHUDWRUVHWRUIXHO

  

tank.

'.HHSD¿UHH[WLQJXLVKHUQHDUE\DQGNQRZLWVSURSHUXVH

 

  Fire extinguishers rated ABC by NFPA are appropriate.

 

E. Store fuel only in an approved container, and only in a well 

  

ventilated 

area.

 

F. Follow local codes for closeness to combustible material.

3. DEADLY EXHAUST GAS - 
Exhaust fumes from any gasoline engine contain carbon monoxide, an 
invisible, odorless and deadly gas that must be mixed with fresh air.

TESTING POLICY

Before any generator is shipped from the factory, it is fully checked 
for performance. The generator is loaded to its full capacity, and the 
voltage, current, and frequency are carefully checked.

Rated output of generator is based on engineering tests of typical units, 
and is subject to, and limited by, the temperature, altitude, fuel, and 

RWKHUFRQGLWLRQVVSHFL¿HGE\WKHPDQXIDFWXUHURIDSSOLFDEOHHQJLQHV

This unit comes factory set for either key start or manual start. With the 
DSE 7310 MKII controller used in the manual start option it is possible 
to wire the control for remote start. Wiring instructions can be found 
further in this manual. The key start version does not have this option.

Summary of Contents for DR100F4

Page 1: ...INC 225 S CORDOVA AVE LE CENTER MN 56057 SERVICE DEPT 507 357 6831 SALES DEPT 507 357 6821 www wincogen com INSTALLATION AND OPERATORS DR20I4 DR130F4 GENERATORS MANUAL DSE 7310 MKII ELECTRIC START DR...

Page 2: ...followed during installation and maintenance of the generator Read and understand all instructions in the manual before starting and operating the generator USING THIS MANUAL Congratulations on your c...

Page 3: ...al word is to be limited to the most extreme situations WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicat...

Page 4: ...975 1D or 2D EN590 or equivalent Oil Type SEE LUBRICATION SECTION Oil Capacity 8 8 Quarts Cooling System 50 50 mix DR30I4 Generator Wattage 29 000 30 000 30 000 30 000 Volts 120 240 120 208 120 240 27...

Page 5: ...r 2D EN590 or equivalent Oil Type SEE LUBRICATION SECTION Oil Capacity 13 5 Quarts Cooling System 50 50 mix DR65F4 Generator Wattage 62 000 62 000 62 000 62 000 Volts 120 240 120 208 120 240 277 480 P...

Page 6: ...2D EN590 or equivalent Oil Type SEE LUBRICATION SECTION Oil Capacity 13 5 Quarts Cooling System 50 50 mix DR100F4 Generator Wattage 100 000 105 000 105 000 115 000 Volts 120 240 120 208 120 240 277 4...

Page 7: ...JRYHUQRU 7KH JHQHUDWRU LV D VLQJOH EHDULQJ GLUHFW GULYH URWDWLQJ HOG GHVLJQ 7KH JHQHUDWRU LV FRQQHFWHG WR WKH HQJLQH ZKHHO YLD H LEOH drive disks Generator set is skid mounted with isolation mounts b...

Page 8: ...G DQG EXLOW ZLWK DQ 0 6SHF L H 0 QXPEHU ZKLFK FDQ be found on the WINPOWER data tag When the M Spec is present supplemental inserts will accompany this standard manual providing information about the...

Page 9: ...omply with all national state and local codes Before beginning the installation process recheck the voltage phase and amperage rating of the generator set Be certain it can handle the intended load an...

Page 10: ...and to be very toxic These engine generator sets are all NEGATIVE ground Be very careful not to connect the battery in reverse polarity as this may short circuit the battery charging system on the en...

Page 11: ...done by a licensed electrician and must conform to the National Electrical Code and comply with all the local codes and regulations Check with the local authorities before proceeding INSTALLATION NOT...

Page 12: ...ator in a stand alone application This would be an application where there is not a distribution panel and no other ground to neutral bond in the wiring V VWHP I D JURXQGLQJ ZLUH LV DWWDFKHG KHUH UHPR...

Page 13: ...LAYOUT STOP RESET This button places the module into its Stop Reset mode This will clear any alarm conditions for which the triggering FULWHULD KDYH EHHQ UHPRYHG 7KH IXHO VXSSO GH HQHUJL HV DQG WKH en...

Page 14: ...pending on which model you have and a frequency of 59 5 to 60 5 KHUW If you have the proper voltage at the generator the next step is to check the voltage at the generator terminals in the Automatic T...

Page 15: ...Problem Possible Causes Unit will not crank when power fails Digital genset not in AUTO Transfer control switch not in AUTOMATIC position Incorrect wiring between ATS and genset Defective control rel...

Page 16: ...HW 2 USE 2 XHH XHHW XHHW 2 ZW 2 44 57 75 88 101 114 132 154 176 202 224 251 273 295 334 370 405 418 431 458 480 519 550 572 585 50 68 86 100 118 137 155 177 205 237 264 291 319 346 391 432 473 487 505...

Page 17: ...1 5 3 27 5 67 57 62 12 2 22 17 8 7 7 21 1 1 51 66 211 725 8 1 0 67 57 5 3 8 3803 7 7 51 725 8 9 6 1 5 2 35 6685 6 1 5 22 17 7 03 6 1 5 3 27 5 67 57 62 12 2 3 8 5 1 725 2 3 8 6 2 22 17 8 7 7 21 1 1 51...

Page 18: ...8 2 2 2 9 4958 552 4 36 9 4958 9 8 2 5 6 9 9 8 2 8 2 2 9 4958 8 2 8 5 6 259 8 2 4583 22 5 6 2 9 2 9 2 9 53 49 4 4 52 9 2 2 2 9 4 9 8 89 2 2 9 4958 2 2 9 4958 36 9 8 89 9 8 77 77 67 57 1 6723 6723 6 5...

Page 19: ...09 REV B THREE PHASE AC WIRE HIGH AND LOW WYE THREE PHASE HIGH WYE 277 480V THREE PHASE LOW WYE 120 208V THREE PHASE WIRING DELTA THREE PHASE DELTA 120 240V SINGLE PHASE AC WIRING 4 LEAD SINGLE PHASE...

Page 20: ...KRXUV ZKLFK HYHU RFFXUV UVW IURP GDWH RI SXUFKDVH Q QR HYHQW LV 1 2 liable for incidental or consequential damages Note Some states do not allow limitation on the duration of implied warranty and some...