ENGINE

Refer to the engine operators manual for more detailed operation and 
maintenance information.

CAUTION: EQUIPMENT DAMAGE:

%HVXUHWRFKHFNWKHHQJLQHRLOOHYHOIUHTXHQWO\DVVSHFL¿HGLQWKH

engine manual.

The engine manufacturer has established an excellent worldwide 

HQJLQHVHUYLFHRUJDQL]DWLRQHQJLQHVHUYLFHLVDYDLODEOHIURPDQHDUE\
DXWKRUL]HGGHDOHURUGLVWULEXWRU*RWRWKH:,1&2ZHEVLWHIRUDOLVWRI
HQJLQHGHDOHUVKWWSZLQFRJHQFRP(QJLQHB6XSSRUWRUFRQWDFWWKH

WINCO Service Department.

The rated power of each engine-generator is limited by the 

WHPSHUDWXUHDOWLWXGHDQGDOORWKHUDPELHQWFRQGLWLRQVVSHFL¿HGE\

the engine manufacturer. Engine power may decrease 3½% for each 
1000 feet above sea level, and will decrease an additional 1% for each 
10 degrees Fahrenheit above 60° Fahrenheit. Units should not be 
operated in ambient temperature greater than 125° Fahrenheit.

GENERATOR

:,1&2JHQHUDWRUVHWVXVHEUXVKOHVV$95$XWR9ROWDJH5HJXODWRU

controlled broad-range generator ends. The generator converts 
rotational mechanical energy into electrical energy. These WINCO units 
are equipped with generators manufactured by Cummins Generator 
Technology. Each generator ‘end’ has its own data tag. A unique serial 
number is on the data plate.

MODEL NUMBER STRUCTURE

The WINPOWER alpha-numerical numbering consists of a base model 
designation, followed by an options section, separated by a dash mark. 
The base component of the model numbering system identifies an 
engine type, engine starting method, fuel type, kilowatt rating, engine 
manufacturer, and number of generator poles. Following the separation 
dash mark is the voltage connection and optional installed equipment. 

2SWLRQVLQFOXGHIHDWXUHVOLNHZHDWKHUHQFORVXUHVKRXVLQJEDVH
PRXQWHGIXHOWDQNVL]HVDQGWUDLOHURSWLRQV

Please note that some features or packages, such as NFPA level I 
& II, do not have an indication place in this numbering system. They 

DUHLVVXHGDQGEXLOWZLWKDQ06SHFLH0QXPEHUZKLFKFDQ

be found on the WINPOWER data tag. When the M-Spec is present, 
supplemental inserts will accompany this standard manual providing 
information about the special equipment and features installed. The 
standard model numbering key that can be used along with the data 
tag information and/or M-Spec supplements to determine the generator 
set’s ratings and specifications.

D

D = Diesel

R

R = Remote Start

30

Generator Output Rating in kW

I

(QJLQH0DQXIDFWXUHU, ,VX]X) )37

4

Number of Generator Poles

-

Base Unit - Options Separator

A

Voltage

$ 6LQJOH3KDVH9
' 7KUHH3KDVH9
- 7KUHH3KDVH9
/ 7KUHH3KDVH9

A

HOUSING TYPE
A = Sound Attenuated/Weather Protective
* = No Housing

M

)XHO7DQN6L]H6 6PDOO0 0HGLXP/ /DUJH
      3 3ODVWLF 1RQH

T

7 7UDLOHU 1RQH

D

Battery Charger Options

$ 9$% 9$& 9$' 9$
( 9$1)3$) 9$1)3$* 9$
+ 9$, 9$1)3$- 9$
. 9'&$'6(/ 9'&$'6(

PREPARING THE UNIT

UNPACKING

1. As you receive your unit, it is critical to check it for any damage. If 
any damage is noted, it is always easiest to refuse the shipment and 
let WINCO take care of the freight claim. If you sign for the unit, the 

WUDQVIHURIWKHRZQHUVKLSUHTXLUHVWKDW\RX¿OHWKHIUHLJKWFODLP

2. Before proceeding with the preparations of your new generator 
for operation, take a couple of minutes to ensure the unit you have 

UHFHLYHGLVWKHFRUUHFWPRGHODQGUHYLHZWKHVSHFL¿FDWLRQSDJHVLQWKLV

manual to ensure that this unit meets your job requirements.

CAUTION: EQUIPMENT DAMAGE:
This unit is shipped with oil and a 50/50 mix of coolant. Be sure to 

FKHFNDOOÀXLGOHYHOVEHIRUHRSHUDWLQJ6HHHQJLQHPDQXIDFWXUHU¶V

instruction manual for recommended oil requirements before initial 
starting.

Once generator set is on-site:
1. Carefully remove the crate.
2. After inspecting the engine-generator for external, physical damage, 
  locate and check the following items packed with the unit:
    a. Installation and Operator’s Manual.
    b. Engine manufacturer’s instruction manual.
    c. Battery hold-down brackets & hardware.
    d. Unit components or accessory items shipped loose for on-site 
   installation.
  e. 

Optional 

accessories.

3. Remove main frame hold-down bolts.
4. Unit can now be lifted from shipping rails.

Summary of Contents for DR100F4

Page 1: ...INC 225 S CORDOVA AVE LE CENTER MN 56057 SERVICE DEPT 507 357 6831 SALES DEPT 507 357 6821 www wincogen com INSTALLATION AND OPERATORS DR20I4 DR130F4 GENERATORS MANUAL DSE 7310 MKII ELECTRIC START DR...

Page 2: ...followed during installation and maintenance of the generator Read and understand all instructions in the manual before starting and operating the generator USING THIS MANUAL Congratulations on your c...

Page 3: ...al word is to be limited to the most extreme situations WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicat...

Page 4: ...975 1D or 2D EN590 or equivalent Oil Type SEE LUBRICATION SECTION Oil Capacity 8 8 Quarts Cooling System 50 50 mix DR30I4 Generator Wattage 29 000 30 000 30 000 30 000 Volts 120 240 120 208 120 240 27...

Page 5: ...r 2D EN590 or equivalent Oil Type SEE LUBRICATION SECTION Oil Capacity 13 5 Quarts Cooling System 50 50 mix DR65F4 Generator Wattage 62 000 62 000 62 000 62 000 Volts 120 240 120 208 120 240 277 480 P...

Page 6: ...2D EN590 or equivalent Oil Type SEE LUBRICATION SECTION Oil Capacity 13 5 Quarts Cooling System 50 50 mix DR100F4 Generator Wattage 100 000 105 000 105 000 115 000 Volts 120 240 120 208 120 240 277 4...

Page 7: ...JRYHUQRU 7KH JHQHUDWRU LV D VLQJOH EHDULQJ GLUHFW GULYH URWDWLQJ HOG GHVLJQ 7KH JHQHUDWRU LV FRQQHFWHG WR WKH HQJLQH ZKHHO YLD H LEOH drive disks Generator set is skid mounted with isolation mounts b...

Page 8: ...G DQG EXLOW ZLWK DQ 0 6SHF L H 0 QXPEHU ZKLFK FDQ be found on the WINPOWER data tag When the M Spec is present supplemental inserts will accompany this standard manual providing information about the...

Page 9: ...omply with all national state and local codes Before beginning the installation process recheck the voltage phase and amperage rating of the generator set Be certain it can handle the intended load an...

Page 10: ...and to be very toxic These engine generator sets are all NEGATIVE ground Be very careful not to connect the battery in reverse polarity as this may short circuit the battery charging system on the en...

Page 11: ...done by a licensed electrician and must conform to the National Electrical Code and comply with all the local codes and regulations Check with the local authorities before proceeding INSTALLATION NOT...

Page 12: ...ator in a stand alone application This would be an application where there is not a distribution panel and no other ground to neutral bond in the wiring V VWHP I D JURXQGLQJ ZLUH LV DWWDFKHG KHUH UHPR...

Page 13: ...LAYOUT STOP RESET This button places the module into its Stop Reset mode This will clear any alarm conditions for which the triggering FULWHULD KDYH EHHQ UHPRYHG 7KH IXHO VXSSO GH HQHUJL HV DQG WKH en...

Page 14: ...pending on which model you have and a frequency of 59 5 to 60 5 KHUW If you have the proper voltage at the generator the next step is to check the voltage at the generator terminals in the Automatic T...

Page 15: ...Problem Possible Causes Unit will not crank when power fails Digital genset not in AUTO Transfer control switch not in AUTOMATIC position Incorrect wiring between ATS and genset Defective control rel...

Page 16: ...HW 2 USE 2 XHH XHHW XHHW 2 ZW 2 44 57 75 88 101 114 132 154 176 202 224 251 273 295 334 370 405 418 431 458 480 519 550 572 585 50 68 86 100 118 137 155 177 205 237 264 291 319 346 391 432 473 487 505...

Page 17: ...1 5 3 27 5 67 57 62 12 2 22 17 8 7 7 21 1 1 51 66 211 725 8 1 0 67 57 5 3 8 3803 7 7 51 725 8 9 6 1 5 2 35 6685 6 1 5 22 17 7 03 6 1 5 3 27 5 67 57 62 12 2 3 8 5 1 725 2 3 8 6 2 22 17 8 7 7 21 1 1 51...

Page 18: ...8 2 2 2 9 4958 552 4 36 9 4958 9 8 2 5 6 9 9 8 2 8 2 2 9 4958 8 2 8 5 6 259 8 2 4583 22 5 6 2 9 2 9 2 9 53 49 4 4 52 9 2 2 2 9 4 9 8 89 2 2 9 4958 2 2 9 4958 36 9 8 89 9 8 77 77 67 57 1 6723 6723 6 5...

Page 19: ...09 REV B THREE PHASE AC WIRE HIGH AND LOW WYE THREE PHASE HIGH WYE 277 480V THREE PHASE LOW WYE 120 208V THREE PHASE WIRING DELTA THREE PHASE DELTA 120 240V SINGLE PHASE AC WIRING 4 LEAD SINGLE PHASE...

Page 20: ...KRXUV ZKLFK HYHU RFFXUV UVW IURP GDWH RI SXUFKDVH Q QR HYHQW LV 1 2 liable for incidental or consequential damages Note Some states do not allow limitation on the duration of implied warranty and some...

Reviews: