Installation and operating instructions Wilo-Sub TWU 3-...-HS (High Speed) 15

INSTALLATION English

9.  Place two scantlings over the well shaft. Lower 

the unit until the supporting clamp is in resting on 
the scantlings.

10.  Disassemble the mounting bracket from the 

discharge pipe and fit the well closure (e.g. well 

cover) on the discharge pipe.

WARNING: Danger of crushing! 

During installation, the entire weight of the 

unit is borne by the lifting equipment and the 

bearer cable may be under tension. This can 

result in severe crushing! Before disassem-

bling the mounting bracket, make sure that 

the bearer cable is NOT under tension! 

11.  Fasten the lifting equipment to the well closure 

and hoist the entire unit (consisting of the pump, 
piping and well closure).

12.  Disassemble the supporting clamp, remove the 

scantlings and lay the power supply cable through 
the well closure to the outside.

13.  Place the unit on the well and fasten the well 

closure.

14.  Fit the discharge pipeline to the tap on the well 

closure and lay the power supply cable to the 
switchbox.

Installing piping for deep wells

Long piping is needed for deep wells. With 

lengths of 10 m or more, impermissible bending 

tension may occur when lifting the piping and it 
may become damaged.
To prevent this, the piping must be installed suc-
cessively in short lengths.
To do this, the individual sections (recommenda-

tion: max. 3 m) are lowered into the borehole and 

installed one after the other. This way, longer 
piping can be installed for deep wells without any 
problems.

NOTE:

 

Metallic pressure pipes must be integrated in 
the potential equalisation in accordance with 
the locally applicable regulations and recog-

nized rules of technology:

•  Since the external frequency converter has 

an insulating effect, note that the pipeline 

upstream and downstream of the frequency 

converter as well as the pump unit are integrat-

ed into the potential equalization.

•  Note the extensive, impedance connection of 

the contacts!

Installing flexible piping

The pump can also be used with flexible piping 
(e.g. hoses). In this case, the piping is fitted to the 

pressure connection and then lowered into the 
borehole together with the pump.

Note:

• Nylon or stainless steel guys are used to lower the 

pump.

• 

The guy must have sufficient bearing capacity for 

the complete system (pump, piping, cable, water 
column).

• The guy must be fastened to the suspension 

points (eyelets) provided on the pressure port 
for that purpose. If these suspension points are 

not available, an intermediate flange containing 

suspension points must be installed.

DANGER 

due to improper fixation.

 

The guy must not be wound around the pres-

sure port or affixed to the piping. This could 

result in slipping or the piping might become 

separated. There is an increased risk of injury! 

Always fasten the guy to the prescribed sus-

pension points! 

5.3.3 

Horizontal installation of the pump

This installation method is only permissible in 
conjunction with a cooling jacket. The pump is 
installed directly in the water tank/reservoir and 

flanged onto the discharge pipeline. The cool

-

ing jacket's supports have to be installed at the 

specified distance in order to prevent bending of 

the unit. For more information, see the installa-
tion and operating instructions for the cooling 
jacket in question.

The connected piping must be self-supporting, 

i.e. it must not be supported by the unit.

In the case of horizontal installation, the pump 

and piping are installed separately. Make sure 
that the pressure connection for the pump and 
the pressure connection for the piping are at the 
same height.

1.  Drill the mounting holes for the support into the 

floor of the operating space (tank/reservoir). See 

the relevant instructions for information about 
the anchor bolts, distances between holes and 

size of holes. Pay attention to the required tight

-

ness of screws and anchors.

2. 

Fasten the supports to the floor and move the 

pump into the correct position using suitable 
hoisting gear.

3. 

Fasten the pump to the supports with the fixation 

material provided. Make sure that the rating plate 
faces upwards!

4. 

Once the pump has been firmly installed, the pipe 

system can be mounted or a pipe system installed 
previously can be attached. Make sure that the 
pressure connections are at the same height.

5.  Connect the discharge pipe to the pressure con-

nection. The threaded connection must be sealed. 
Make sure that the pipe system was installed 
vibration-free and stress-free (if necessary, use 
elastic adaptors).

6.  Lay the cable in such a way that it does not pose 

a danger to anyone (maintenance personnel, etc.) 
at any time (during operation, during mainte-
nance work, etc.). The power supply cables must 
not be damaged. The electrical connections must 
be carried out by an authorised expert.

Summary of Contents for Sub TWU 3-HS Series

Page 1: ...6063546 Ed 05 05 2019 WH Pioneering for You Wilo Sub TWU 3 HS High Speed en Installation and operating instructions...

Page 2: ...Fig 1 Fig 1 Fig 1 Fig 3 Fig 2 TWU 3 HS ECP TWU 3 HS I 1 2 3 4 5 1 2 3 6 4 5 1 2 3 ca 2 l min 0 20 m min 0 30 m 7 8 3 1 1 2 4 5 6 6 1 1 1 1 TWU 3 HS E CP TWU 3 HS I 7...

Page 3: ...Fig 1 Fig 1 Fig 5 Fig 6 Fig 4 1 4 2 3 ON OFF RESET PUMP ON FAILURE LINE 1 2 3 1 5 5 4 4 2 3 6 7 8...

Page 4: ...Fig 10 Fig 11 Fig 9 Fig 8 Fig 7 1 2 3 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 2 1...

Page 5: ...1 Delivery 12 4 2 Transport 12 4 3 Storage 12 4 4 Return delivery 13 5 Installation 13 5 1 General 13 5 2 Installation types 13 5 3 Installation 13 5 4 Dry running protection 16 5 5 Electrical connect...

Page 6: ...ss consent of the manufacturer The illustrations used may differ from the original and are only intended as an exemplary representation of the pumps 1 4 Subject to change The manufacturer reserves the...

Page 7: ...refer to personal injury appear in black and are always accompanied by a safety symbol Danger prohibition or instruction symbols are used as safety symbols Example Danger symbol General hazard Danger...

Page 8: ...n again until the error has been corrected When the pump is connected to the electrical control panel particularly when electronic devices such as soft start up control or frequency con verters are us...

Page 9: ...wimming pools or other basins that can be entered there is a risk of electrocution Note Use is strictly forbidden if there are people in the basin If there are no people in the basin protec tive measu...

Page 10: ...fluid To do this the external frequency converter must be installed in the ascending pipe The internal frequency converter is cooled by the surrounding fluid The frequency converter offers the monitor...

Page 11: ...0 1 min Max immersion depth 150 m Submerged OTS S1 Non immersed OTE Max switching frequency 30 h Max sand content 50 g m Min flow at motor 0 08 m s Pressure connection TWU TWU 3 HS I TWU 3 02 3 03 HS...

Page 12: ...ast 1 year The pump should be cleaned thoroughly before it is put into temporary storage Consider the following for storage Place the pump on a firm bearing surface and se cure it against slipping and...

Page 13: ...tal injury Take all necessary safety precautions to prevent this When installing the pump note the following This work must be performed by qualified per sonnel and electrical work must be performed b...

Page 14: ...material which would mean that the motor cooling is no longer guaranteed This would result in increased wear of the hydraulics To prevent this it may be neces sary to use a cooling jacket or install...

Page 15: ...ty for the complete system pump piping cable water column The guy must be fastened to the suspension points eyelets provided on the pressure port for that purpose If these suspension points are not av...

Page 16: ...tion point a second switch ing point additional electrode is used to obtain a sufficient difference between the activation and deactivation points This prevents constant switching This function can be...

Page 17: ...o extend the power supply cable this ensures that the cable inlet on the frequency converter seals properly 1 Measure with an insulation tester measuring voltage is 500 V to measure the resistance of...

Page 18: ...rotection should be set to the rated current shown on the rating plate At partial load we recommend that the motor pro tection be set 5 above the current measured at the duty point 6 Commissioning The...

Page 19: ...on after a specified time Leak monitoring Rotation direction monitoring and switching of rotation direction Additional connection for functional extension Fig 6 Operating elements Display 1 Green LED...

Page 20: ...pressure for defining the start up pressure When you open a tap the pressure in the system drops The Dp Start differential pressure can be set in order to prevent the pump from starting each time a t...

Page 21: ...ump is switched on it must be switched off without delay The start pauses specified in the Technical data section must be observed before starting up again If the fault recurs the unit must be switche...

Page 22: ...or safety reasons Only auxiliary lifting devices that are in a techni cally perfect condition and lifting gear that has been officially approved may be used for lowering and raising the pump RISK of d...

Page 23: ...he European Union this symbol can appear on the product the packaging or the accompa nying documentation It means that the electri cal and electronic products in question must not be disposed of along...

Page 24: ...rror in the internal serial com munication of the frequency converter Contact Wilo customer service 9 E9 Overpressure The set limit value P limit was exceeded If the error repeats check the P limit pa...

Page 25: ...pump curve or install a unit with greater output 9 2 5 Fault The unit does not run smoothly and is noisy 1 Unit is operating in an inadmissible range Check the operational data of the unit and correct...

Page 26: ...0 2 Overview of factory and recommended settings for the TWU 3 HS ECP operating parameters Parameter user Setting range Setting Factory setting Recommended Pmax 1 5 7 5 bar 3 0 bar As required Languag...