Installation and operating instructions Wilo-Sub TWU 3-...-HS (High Speed) 21

COMMISSIONING English

6.4.2  Venting the pump and unit

• Open all the slide valves in the discharge pipeline.
• Switch the pump on. To bypass the built-in dry-

running protection of the TWU 3-...-HS-ECP, hold 

down the “+” button on the frequency converter. 
The pump starts pumping at maximum output.

The air escapes through the corresponding air 

vent valves. If you have not installed any air 

vent valves, open the taps so that the air can 

escape from them!

• Once the pump and pipe system have been 

vented, switch the pump off again. To do this 

with the TWU 3-...-HS-ECP, press the “ON/OFF” 

button on the frequency converter.

6.4.3  Before switching on

Check the following prior to switching on the 

submersible pump:

• Proper and secure cable routing (e.g. no loops)
• 

Firm fit of all components (pump, piping, etc.)

• 

Operating conditions:

• 

Temperature of the fluid

• Immersion depth 
• Ambient temperature when external frequency 

converter is used

• Open all the gate valves in the pressure pipe. The 

pump must not be switched off when the valves 
are throttled or closed.

6.4.4  Switching on

• Pump with built-in frequency converter 

(TWU 3-...-HS-I)

The pump does not have an automatic activa-
tion function and has to be switched on and off 
manually using a separate operating point  
(on/off switch) provided by the customer. A 
separate pressure controller must be installed for 
automatic operation.

• Pump with external frequency converter 

(TWU 3-...-HS-ECP)

The pump is now in standby mode and “Stand-
by” is shown on the display. To switch the pump 
on, press the “ON/OFF” button on the frequency 
converter. The pump starts and either pumps 
water or switches to standby mode, depending 
on the operating conditions. When water is drawn 
from a tap, the pump starts and provides the 
desired water pressure. When no more water is 
being drawn, the pump switches back to standby 
mode.

6.4.5  After switching on

The rated current is briefly exceeded during the 

start-up procedure. Once the start-up procedure 
has completed, the operating current may no 
longer exceed the rated current.

If the motor does not start immediately after the 
pump is switched on, it must be switched off 

without delay. The start pauses specified in the 

“Technical data” section must be observed before 
starting up again. If the fault recurs, the unit must 
be switched off again immediately. The pump 
should only be restarted once the fault has been 

rectified.

6.5  Conduct during operation

When operating the pump, always follow the 
locally applicable laws and regulations for work 
safety, accident prevention and handling electri-

cal machinery. The operator is obliged to define 

the responsibilities of employees to help ensure 
safe working practice. All personnel are responsi-
ble for ensuring that regulations are observed.
The pump is equipped with moving parts. During 
operation, these parts rotate in order to pump the 

fluid. Certain substances in the fluid can result in 

very sharp edges forming on the moving parts.

WARNING: rotating parts! 

The rotating parts can crush and sever limbs. 

Never reach into the hydraulics or touch 

the rotating parts when the machine is in 

operation. Before performing maintenance or 

repairs, switch off the pump and wait for the 

rotating parts to come to a standstill!

The following must be checked at regular inter-

vals:

• 

Operating voltage (permissible dev/- 5 % 

of the rated voltage)

• 

Frequency (permissible dev/- 2 % of the 

rated frequency)

• Current consumption (permissible deviation  

between phases is a maximum of 5 %)

• Switching frequency (see technical data)
• Minimum water submersion
• 

Quiet and low-vibration running

• Gate valves in the pressure pipe must be open.

6.6 

Auxiliary contact (TWU 3-...-HS-ECP)

The frequency converter is prepared for connect-
ing an auxiliary contact, which is factory-set for 
use in single or dual pump operation.
Contact Wilo customer service to use other func-
tions of the auxiliary contact.
The associated menu is not enabled by default.
The following functions are available depending 

on the menu item setting:

• 

1 <->

 = normal or dual operation (factory setting) 

In this setting, the pump can work as an inde-
pendent system or as a double-pump system 
together with a second system.

• 

2 <-

 = remote operation 

The system is switched on and off via remote 
control. This is used, for example, if the pump is 
only allowed to start when all the inlet slide valves 
are open. The control for the inlet slide valves can 
be linked to the auxiliary contact in this case.

Summary of Contents for Sub TWU 3-HS Series

Page 1: ...6063546 Ed 05 05 2019 WH Pioneering for You Wilo Sub TWU 3 HS High Speed en Installation and operating instructions...

Page 2: ...Fig 1 Fig 1 Fig 1 Fig 3 Fig 2 TWU 3 HS ECP TWU 3 HS I 1 2 3 4 5 1 2 3 6 4 5 1 2 3 ca 2 l min 0 20 m min 0 30 m 7 8 3 1 1 2 4 5 6 6 1 1 1 1 TWU 3 HS E CP TWU 3 HS I 7...

Page 3: ...Fig 1 Fig 1 Fig 5 Fig 6 Fig 4 1 4 2 3 ON OFF RESET PUMP ON FAILURE LINE 1 2 3 1 5 5 4 4 2 3 6 7 8...

Page 4: ...Fig 10 Fig 11 Fig 9 Fig 8 Fig 7 1 2 3 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 2 1...

Page 5: ...1 Delivery 12 4 2 Transport 12 4 3 Storage 12 4 4 Return delivery 13 5 Installation 13 5 1 General 13 5 2 Installation types 13 5 3 Installation 13 5 4 Dry running protection 16 5 5 Electrical connect...

Page 6: ...ss consent of the manufacturer The illustrations used may differ from the original and are only intended as an exemplary representation of the pumps 1 4 Subject to change The manufacturer reserves the...

Page 7: ...refer to personal injury appear in black and are always accompanied by a safety symbol Danger prohibition or instruction symbols are used as safety symbols Example Danger symbol General hazard Danger...

Page 8: ...n again until the error has been corrected When the pump is connected to the electrical control panel particularly when electronic devices such as soft start up control or frequency con verters are us...

Page 9: ...wimming pools or other basins that can be entered there is a risk of electrocution Note Use is strictly forbidden if there are people in the basin If there are no people in the basin protec tive measu...

Page 10: ...fluid To do this the external frequency converter must be installed in the ascending pipe The internal frequency converter is cooled by the surrounding fluid The frequency converter offers the monitor...

Page 11: ...0 1 min Max immersion depth 150 m Submerged OTS S1 Non immersed OTE Max switching frequency 30 h Max sand content 50 g m Min flow at motor 0 08 m s Pressure connection TWU TWU 3 HS I TWU 3 02 3 03 HS...

Page 12: ...ast 1 year The pump should be cleaned thoroughly before it is put into temporary storage Consider the following for storage Place the pump on a firm bearing surface and se cure it against slipping and...

Page 13: ...tal injury Take all necessary safety precautions to prevent this When installing the pump note the following This work must be performed by qualified per sonnel and electrical work must be performed b...

Page 14: ...material which would mean that the motor cooling is no longer guaranteed This would result in increased wear of the hydraulics To prevent this it may be neces sary to use a cooling jacket or install...

Page 15: ...ty for the complete system pump piping cable water column The guy must be fastened to the suspension points eyelets provided on the pressure port for that purpose If these suspension points are not av...

Page 16: ...tion point a second switch ing point additional electrode is used to obtain a sufficient difference between the activation and deactivation points This prevents constant switching This function can be...

Page 17: ...o extend the power supply cable this ensures that the cable inlet on the frequency converter seals properly 1 Measure with an insulation tester measuring voltage is 500 V to measure the resistance of...

Page 18: ...rotection should be set to the rated current shown on the rating plate At partial load we recommend that the motor pro tection be set 5 above the current measured at the duty point 6 Commissioning The...

Page 19: ...on after a specified time Leak monitoring Rotation direction monitoring and switching of rotation direction Additional connection for functional extension Fig 6 Operating elements Display 1 Green LED...

Page 20: ...pressure for defining the start up pressure When you open a tap the pressure in the system drops The Dp Start differential pressure can be set in order to prevent the pump from starting each time a t...

Page 21: ...ump is switched on it must be switched off without delay The start pauses specified in the Technical data section must be observed before starting up again If the fault recurs the unit must be switche...

Page 22: ...or safety reasons Only auxiliary lifting devices that are in a techni cally perfect condition and lifting gear that has been officially approved may be used for lowering and raising the pump RISK of d...

Page 23: ...he European Union this symbol can appear on the product the packaging or the accompa nying documentation It means that the electri cal and electronic products in question must not be disposed of along...

Page 24: ...rror in the internal serial com munication of the frequency converter Contact Wilo customer service 9 E9 Overpressure The set limit value P limit was exceeded If the error repeats check the P limit pa...

Page 25: ...pump curve or install a unit with greater output 9 2 5 Fault The unit does not run smoothly and is noisy 1 Unit is operating in an inadmissible range Check the operational data of the unit and correct...

Page 26: ...0 2 Overview of factory and recommended settings for the TWU 3 HS ECP operating parameters Parameter user Setting range Setting Factory setting Recommended Pmax 1 5 7 5 bar 3 0 bar As required Languag...

Page 27: ...Pioneering for You avrora arm ru 7 495 956 62 18...

Reviews: