TRANSPORTATION AND STORAGE

3.6  Type key

Example:

Wilo-Sub TWU 3-0305-HS-E-CP

TWU

Submersible pump

3

Diameter of the hydraulics in inches

03

Rated volume flow in m³/h

05

Number of hydraulic stages

HS

High-speed version with speeds of up to 

8400 1/min

E

Frequency converter version
E = external frequency converter
I = internal frequency converter

CP

Control function
CP = constant pressure control via variable 
speed

without = fixed speed of up to 8400 1/min

3.7  Scope of delivery

• Submersible pump with cable
• Installation and operating instructions
• External frequency converter  

(with “HS-ECP” only)

3.8 

Accessories (optionally available)

• Cooling jacket
• Level sensors
• Motor cable kits
• Sealing set for motor cable extension

4  Transportation and storage

4.1  Delivery

On receiving the consignment, check immediately 
that this is complete and undamaged. If any parts 
are damaged or missing, the transport company 

or the manufacturer must be notified on the day 

of delivery since claims made after this date can-
not be recognised. 
Damage to parts must be noted on the freight 
documentation.

4.2  Transport

Only the appropriate and approved lifting gear, 
transportation and hoist may be used. These 

must have sufficient load-bearing capacity to 

ensure that the pump can be transported safely. 
When using chains, these are to be secured 
against slipping.

The personnel must be qualified for the tasks and 

must follow all applicable national safety regula-
tions during the work.
The pump is delivered by the manufacturer or 
shipping agency in suitable packaging. This 
normally precludes the possibility of damage 
occurring during transportation and storage. The 
packaging should be stored in a safe place for 
reuse if the product is frequently used at different 
locations.

4.3  Storage

Newly delivered submersible pumps are prepared 
in such a way that they can be stored for at least 

1 year. The pump should be cleaned thoroughly 

before it is put into temporary storage!

Consider the following for storage:

• 

Place the pump on a firm bearing surface and se

-

cure it against slipping and falling over. Submers-

ible pumps can be stored vertically or horizontally. 
If pumps are stored horizontally in more than 
9 layers, ensure that they do not bend.

Otherwise, impermissible bending tensions can 

arise in the hydraulics and the pump may be 

damaged. Support the hydraulics accordingly!

DANGER due to falling over! 

Never set the unit down unsecured. If the 

pump falls over, this may lead to injuries!

• Submersible pumps can be stored at tempera-

tures down to -15 °C. The store room must be dry. 

We recommend a frost-protected room for stor-

age with temperature between 5 °C and 25 °C.

• The submersible pump is not allowed to be stored 

in rooms in which welding work is carried out, be-
cause the resulting gases or radiation can damage 
the elastomer components and coating.

• The pump's suction and pressure connections 

and the external frequency converter should be 
permanently sealed to prevent contamination.

• The power supply cables should be protected 

against kinking, damage, and moisture.

ELECTRICAL hazard! 

Damaged power supply cables can cause fatal 

injury! Defective cables must be replaced by a 

qualified electrician immediately.

BEWARE of moisture! 

Moisture penetrating the cable will damage 

both the pump and the cable. For this reason, 

never immerse the cable end in the fluid or 

any other liquid.

• The submersible pump and the external fre-

quency converter must be protected from direct 
sunlight, heat, dust, and frost.

• If the submersible pump and the external fre-

quency converter have been stored for a long pe-
riod of time, they should be cleaned of impurities 
such as dust and oil residue before commission-
ing. Check the impeller for ease of movement.

Note: 

 

Elastomer parts and coating are subject to natural 
brittleness. If the product is to be stored for 

longer than 6 months, we recommend check

-

ing these parts and replacing them as necessary. 
Consult the manufacturer for further details.

Summary of Contents for Sub TWU 3-HS Series

Page 1: ...6063546 Ed 05 05 2019 WH Pioneering for You Wilo Sub TWU 3 HS High Speed en Installation and operating instructions...

Page 2: ...Fig 1 Fig 1 Fig 1 Fig 3 Fig 2 TWU 3 HS ECP TWU 3 HS I 1 2 3 4 5 1 2 3 6 4 5 1 2 3 ca 2 l min 0 20 m min 0 30 m 7 8 3 1 1 2 4 5 6 6 1 1 1 1 TWU 3 HS E CP TWU 3 HS I 7...

Page 3: ...Fig 1 Fig 1 Fig 5 Fig 6 Fig 4 1 4 2 3 ON OFF RESET PUMP ON FAILURE LINE 1 2 3 1 5 5 4 4 2 3 6 7 8...

Page 4: ...Fig 10 Fig 11 Fig 9 Fig 8 Fig 7 1 2 3 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 2 1...

Page 5: ...1 Delivery 12 4 2 Transport 12 4 3 Storage 12 4 4 Return delivery 13 5 Installation 13 5 1 General 13 5 2 Installation types 13 5 3 Installation 13 5 4 Dry running protection 16 5 5 Electrical connect...

Page 6: ...ss consent of the manufacturer The illustrations used may differ from the original and are only intended as an exemplary representation of the pumps 1 4 Subject to change The manufacturer reserves the...

Page 7: ...refer to personal injury appear in black and are always accompanied by a safety symbol Danger prohibition or instruction symbols are used as safety symbols Example Danger symbol General hazard Danger...

Page 8: ...n again until the error has been corrected When the pump is connected to the electrical control panel particularly when electronic devices such as soft start up control or frequency con verters are us...

Page 9: ...wimming pools or other basins that can be entered there is a risk of electrocution Note Use is strictly forbidden if there are people in the basin If there are no people in the basin protec tive measu...

Page 10: ...fluid To do this the external frequency converter must be installed in the ascending pipe The internal frequency converter is cooled by the surrounding fluid The frequency converter offers the monitor...

Page 11: ...0 1 min Max immersion depth 150 m Submerged OTS S1 Non immersed OTE Max switching frequency 30 h Max sand content 50 g m Min flow at motor 0 08 m s Pressure connection TWU TWU 3 HS I TWU 3 02 3 03 HS...

Page 12: ...ast 1 year The pump should be cleaned thoroughly before it is put into temporary storage Consider the following for storage Place the pump on a firm bearing surface and se cure it against slipping and...

Page 13: ...tal injury Take all necessary safety precautions to prevent this When installing the pump note the following This work must be performed by qualified per sonnel and electrical work must be performed b...

Page 14: ...material which would mean that the motor cooling is no longer guaranteed This would result in increased wear of the hydraulics To prevent this it may be neces sary to use a cooling jacket or install...

Page 15: ...ty for the complete system pump piping cable water column The guy must be fastened to the suspension points eyelets provided on the pressure port for that purpose If these suspension points are not av...

Page 16: ...tion point a second switch ing point additional electrode is used to obtain a sufficient difference between the activation and deactivation points This prevents constant switching This function can be...

Page 17: ...o extend the power supply cable this ensures that the cable inlet on the frequency converter seals properly 1 Measure with an insulation tester measuring voltage is 500 V to measure the resistance of...

Page 18: ...rotection should be set to the rated current shown on the rating plate At partial load we recommend that the motor pro tection be set 5 above the current measured at the duty point 6 Commissioning The...

Page 19: ...on after a specified time Leak monitoring Rotation direction monitoring and switching of rotation direction Additional connection for functional extension Fig 6 Operating elements Display 1 Green LED...

Page 20: ...pressure for defining the start up pressure When you open a tap the pressure in the system drops The Dp Start differential pressure can be set in order to prevent the pump from starting each time a t...

Page 21: ...ump is switched on it must be switched off without delay The start pauses specified in the Technical data section must be observed before starting up again If the fault recurs the unit must be switche...

Page 22: ...or safety reasons Only auxiliary lifting devices that are in a techni cally perfect condition and lifting gear that has been officially approved may be used for lowering and raising the pump RISK of d...

Page 23: ...he European Union this symbol can appear on the product the packaging or the accompa nying documentation It means that the electri cal and electronic products in question must not be disposed of along...

Page 24: ...rror in the internal serial com munication of the frequency converter Contact Wilo customer service 9 E9 Overpressure The set limit value P limit was exceeded If the error repeats check the P limit pa...

Page 25: ...pump curve or install a unit with greater output 9 2 5 Fault The unit does not run smoothly and is noisy 1 Unit is operating in an inadmissible range Check the operational data of the unit and correct...

Page 26: ...0 2 Overview of factory and recommended settings for the TWU 3 HS ECP operating parameters Parameter user Setting range Setting Factory setting Recommended Pmax 1 5 7 5 bar 3 0 bar As required Languag...

Page 27: ...Pioneering for You avrora arm ru 7 495 956 62 18...

Reviews: