22
English
1.
General
See start of document.
2.
Safety
See start of document.
3. Transport and interim storage
Inspect the pump/system for transport damage
immediately upon arrival. Any transport damage
found must be reported to the carrier within the
prescribed periods.
CAUTION! Risk of damage to the pump!
Risk of damage due to improper handling during
transport or storage.
• The pump may only be hung from or carried
using the handle provided for transport. Never
suspend or carry using the cable!
• The pump should be protected against mois-
ture, frost and physical damage during trans-
port and interim storage.
4. Applications
DANGER! Risk of electric shock!
The pump may not be used for draining swim-
ming-pools / garden ponds or similar places
when there are people in the water.
WARNING! Risk of personal injury!
• The materials are not designed for drinking
water supply.
The pump must not be used for pumping drink-
ing water.
• The pumps must not be used:
• to pump raw sewage containing faeces,
• in potentially explosive locations,
Local regulations must be observed.
The submersible motor pumps of the Wilo-Drain
TS 40 are suitable for removing dirty water and
clear fluids containing solids of max. 10 mm Ø
from shafts, pits and vessels.
They are used:
• for building and surface dewatering,
• in sewage and water-management,
• in environmental and domestic waste disposal,
• in industrial and process engineering. The pumps
• are made from stainless steel (1.4301) and plas-
tic (hydraulic).
• are normally submerged by the flow medium,
• can be installed stationary or transportable, but
only vertically.
5. Product data
5.1 Type code
Example: TS 40/10 A 1-230-50-2-10M KA,
TS
Series: submersible motor pump, waste water
40
Nominal width: 40 = Rp 1½
/10
Maximum pump lift (m): 10, 14
A
A = with float switch, connecting cable with
plug
- = not specified: without float switch,
connecting cable with free cable end for
3~motor
1-230
Mains voltage: 1~230 V, single-phase motor,
3~400 V, three-phase motor
-50
Mains frequency (Hz)
-2
2 poles
-10M KA
Connecting cable length (m): 10
5.2 Technical data
Permissible components of the flow media
Mildly acidic / mildly alkaline,
Chloride content max. 150 mg/l (for 1.4301 / AISI 304),
max. permissible grain size
10 mm
Mains voltage
1 ~ 230 V, ± 10 %, 3 ~ 400 V, ± 10 %
Mains frequency
50 Hz
System of protection
IP 68
Speed
max. 2900 1/min (50 Hz)
max. current consumption
see rating plate
Power input P1
see rating plate
Motor power rating P2
see rating plate
max. flow rate
see rating plate
max. pump lift
see rating plate
Operating mode S1
200 operating hours a year
Operating mode S3 (optimum)
Intermittent service, 25 % (2.5 min mode, 7.5 min break)
recommended operating frequency
20 1/h
max. operating frequency
50 1/h
Nominal width of pipe mount
see rating plate
Temperature range of the flow medium
+3 to 35 °C
max. immersion depth
7 m
Oil filling
ELFOLNA DS 22 or comparable, 410 ml
WILO SE 03/2017