2.6 Global Reset Input (Optional)
The global reset input (POWER_INHIBIT) is provided to force all outputs to be switched
off.
●
connected to GND
Power outputs disabled
●
floating
Power outputs may be enabled by the remote control
DSUB25 female
Pin Signal
Comment
1
NC
reserved
14
NC
reserved
2
NC
reserved
15
NC
reserved
3
NC
reserved
16
NC
reserved
4
NC
reserved
17
NC
reserved
5
NC
reserved
18
NC
reserved
6
NC
reserved
19
NC
reserved
7
NC
reserved
20
NC
reserved
8
NC
reserved
21
NC
reserved
9
NC
reserved
22
NC
reserved
10
NC
reserved
23
NC
reserved
11
NC
reserved
24
NC
reserved
12
NC
reserved
25
GND
Ground of the aux. supply, connected to USB ground
13
POWER_INHIBIT Inhibit input
Table 4: Global Reset Connector Pin Assignment
The signals shall be connected by an isolated contact (e.g. relays), and must not be connected
to other potentials.
The input has an internal 10 kΩ pull-up resistor to 5V and an input impedance of 10 kΩ.
It is possible to invert the logic of this signal by changing a jumper switch inside of the
power box..
Jumper at Pin POWER_INHIBIT Input
Functionality
1 – 2
open
power disabled (INTERLOCK)
connected to GND
power enabled
2 – 3
open
power enabled
connected to GND
power disabled (RESET)
8. June 2010
4