Appendix B: Ordering Information
Standard
0P11
.
xxxx
Special versions for CERN
0M11
.
xxxx
The left side of the ordering number is not descriptive, it is randomly assigned to the
requested module & options configuration. Up to six power modules may be used inside of
one power box.
The following modules are possible (external ventilation necessary):
Module Type
Channels per
Module
Optimal Voltage
Range
Peak Output
Current
Continuous
Output Power
MDC
2
2V ... 7V/8V
2*55A
2*300W
MDC
2
5/7V ... 15/16V
2*22A
2*300W
MDC
2
7V ... 24 V
2*11.5A
2*250W
MDC
2
30V ... 60V
2*6.6A
2*300W
The following modules can be used without external ventilation (integrated fans):
Module Type
Channels per
Module
Optimal Voltage
Range
Peak Output
Current
Continuous
Output Power
MDH
2
2V ... 7V/8V
2*30A
2*210W
MDH
2
5/7V ... 15/16V
2*20A
2*250W
MDH
2
7V...24V
11.5A
2*275W
MEH
1
2...7V
115A
550W
MEH
1
6...10V
80A
550W
MEH
1
7...16V
46A
550W
MEH
1
12...30V
23A
550W
MEH
1
30...60V
13.5A
550W
All power modules can be ordered with different sense regulation characteristics:
●
Fast
Fastest regulation, but may be instable if connected to cables longer
than 1 m.
●
Moderate
This is the standard configuration for cable length up to 30 m
●
Slow
This is used for much longer cables
Available Power Bins:
Ordering Number
Power Bin (MARA) 3U
0B15.1200
Power Bin (MARA) 6U, for two power boxes
0B14.2400
8. June 2010
21
*00679.A1