Advanced Bulk System
27
Issue
Steps to Resolve
The tank is not dispensing liquid correctly.
1. Check to ensure the valves on the front of the unit are in the correct position.
2. Check all fittings for cracks or leaks.
3. Check all hydraulic hoses for cracks or leaks.
4. Check the motor to ensure it is rotating in the correct direction.
5. Check the Tank Isolation Valves and ensure they are in the OPEN position.
6. Check the Pressure Gauge to make sure that the pressure level is registering when the
motor is running.
7. If the Pressure Gauge is running above its normal range, it is time to replace your Spin-
on Filter. Replace and check your Pressure Gauge again.
8. Check and clean the Dispensing Faucet to remove dirt, debris, or clogs.
9. Check the o-ring on the Dispensing Faucet. Replace if necessary.
The motor stops working.
The Stop or Start Buttons do not light up
correctly.
1. Check electrical enclosure to ensure power is applied to the pump.
2. Check all circuit breakers to ensure power is available. Check the power cord from the
electrical enclosure to the motor for cracks or problems.
3. Check the power cord connector at the motor to ensure all the pins are seated correctly
and that the connector is clean of dirt and debris.
4. Check that the Emergency System Stop Button is not set to the off position.
5. Have an electrician consult the electrical system specification to troubleshoot the
system.
1. Ensure the power supply to the motor set is on.
2. Have an electrician consult the electrical system specification to troubleshoot the
system.