7. INITIAL OPERATION
IMPORTANT:
•
Follow these steps the very first time you use your system.
CAUTION!
Personal Protective Equipment (“PPE”) should be worn when installing and operating this system. ALWAYS
monitor the system whenever the pump is running or fluid is dispensing.
System Operating Pressure should NEVER exceed 300 PSI. System operating pressures can be regulated
by adjusting pump bypass relief valves located on pump heads to suit specific lubricant viscosities and
temperatures.
System SHOULD NOT be operated in a location with an ambient room temperature less than 60°F/15°C
Contact the manufacturer for more information relating to service in cold environments.
WARNING!
The Tank Isolation Valves (located on the underside of each tank) must be in the open position when
operating the system and in the closed position when servicing the system.
The first time the system is used there will be some air that has been trapped in the hoses. This is normal and will not affect the system. Simply wait for the
air to stop coming out of the lines and fluids to dispense normally before continuing. If air continues to come out of the hoses after the initial use, there may
be a problem with a seal or a hose.
See the Troubleshooting section (page 26)
of this manual, or contact your supplier for additional support. Ensure
that the Tank Isolation Valves located on the underside of each tank are in the open position before continuing.
Using the Operating Valve Handles
Each tank assembly has two operating valve handles located on the front of the Tank Pod. The position of these handles will determine how your system
will pump the fluid. There will be a placard on the front of the Tank Pod indicating which position the handles will need to be in for each setting.
To fill the tank(s) – place both valves in the “UP” position, so the handle is parallel to the ground. To re-circulate the fluid in the tank(s), turn the left-side
handle (above the inlet valve) so it is perpendicular to the floor, and keep the right-side handle parallel to the floor. To dispense the fluid in the tank(s)
(normal operation), turn both handles to be perpendicular to the floor.
OPERATING VALVE POSITIONS
FILL
RECIRCULATE
DISPENSE
Left – Up
Left – Down
Left – Down
Right – Up
Right – Up
Right – Down