7. INITIAL OPERATION
Dispenser Faucets (continued)
NOTE:
Due to the air that has been trapped in the hoses during assembly, air will come out of the faucet initially. Keep the
faucet in the open position until fluid is flowing at a steady pace.
CAUTION!
Do not wedge anything under the handle to force it to stay open.
NOTE:
Leaving the pump running against a closed Dispensing Faucet will not cause a pressure problem with the
System, provided the pump pressure bypass relief valves on each pump have first been set to suit the particular
oil viscosity and ambient room temperature, as the fluid will bypass back to the corresponding Bulk Tank via the
pump bypass pressure return hose.
Normal System operating pressure should be less than 240 PSI when pumping against a closed faucet and
should never exceed 300 PSI. Refer to the Trouble Shooting section at the rear of this manual for the bypass valve
pressure setting procedure should your system operating pressure require adjustment. When the system is
running, it should be monitored AT ALL TIMES.