8. Maintenance Checklist
EVERY 6 MONTHS:
4
Flush out the spill transport pallet (bottom of the pods) with hot water and cleaner/degreasing fluid.
4
Use a clean and damp rag and wipe down the motor and all painted surface areas.
4
Polish all stainless steel areas with stainless steel cleaner.
4
Dust the motor fan.
4
Check tension on Static Discharge Reel.
• If additional tension is needed, apply a wrench to the flats on the mainspring shaft, rotating counter-clockwise until the desired tension is
reached.
• If mainspring tension is too high, it may be decreased by depressing tension lock spring on the opposite side of the reel. DO NOT remove more
tension than desired. If too much tension is removed, increase tension as described above.
4
Inspect the Static Discharge Cable for fraying. Lubrication is not required for the reel.