Advanced Bulk System
19
CAUTION!
Care must be taken when reeling cable back onto the reel.
DO NOT
let go of the cable – walk it back
towards the reel, keeping tension on cable at all times.
7. INITIAL OPERATION
Filling the Tank(s)
(
See Figure 13 and Figure 14 for details)
STEP 4.
Remove the fill port inlet end cap of the appropriate tank by lifting the tabs and pulling the end cap off. Clean the inlet of any debris before
continuing.
See Figure 13.
STEP 5.
Attach the coupling-end of the Suction Hose Assembly to the front of the unit.
See Figure 14.
STEP 6.
Put the operating valve handles for the tank in the “Fill” position (up and up) and also ensure the dispensing faucets are in the closed position.
STEP 7.
Press the START button above the corresponding Dispensing Faucet to begin loading the Bulk Tank.
STEP 8.
Monitor the Bulk Tank Fluid Level Gauge to avoid over-flow situations.
STEP 9.
When the tank is full, raise the suction tube vertically out of the oil drum and allow the pump to pull through any residual oil remaining in the
suction hose assembly then press the STOP button above the Dispensing Faucet to turn off the pump.
STEP 10.
Remove the hose from the fill port inlet, replace the inlet end cap and then store the suction hose assembly for future use.
STEP 11.
Remove the Static Discharge Clip.
FIGURE 13:
Remove Fill Port Inlet End Cap
FIGURE 14:
Attach Suction Hose Assembly to Fill Port Inlet