![Whitmore OilSafe Advanced Bulk System Owner'S Manual Download Page 16](http://html1.mh-extra.com/html/whitmore/oilsafe-advanced-bulk-system/oilsafe-advanced-bulk-system_owners-manual_977314016.webp)
14
5. INSTALLATION
Installing the Desiccant Air Breather
(
See Figure 9 for details)
STEP 17.
Install the Desiccant Air Breather air filter to each tank by screwing it (clockwise) into the threaded opening on the top right of the Bulk Tank.
Remove the elastic white band on the top of the Desiccant Air Breather to activate the breather.
STEP 18.
Install the Spin-on Filter as follows (if not already installed);
a.
Ensure all sealing surfaces are clean and free of damage.
b.
Apply a light film of clean oil to the sealing surfaces of the filter gasket (NOTE – never use grease to lubricate the gasket)
and then carefully insert the sealing gasket into the mating female annular seat in the filter head being sure to attain a
firm flush seat with the gasket.
c.
Screw the new filter element on carefully, avoiding cross-threading. After the sealing gasket contacts the mounting base,
tighten the filter with a Spin-on Filter wrench (not provided) per the instructions found on the filter.
DO NOT OVERTIGHTEN.
FIGURE 9:
Install Desiccant Air Breather