www.whisperkool.com | Page 3
QUICK REFERENCE GUIDE
Controller Layout
Note:
Refer to page 27 for complete listing of buttons and symbols.
°
F
Evaporator Fan
Cellar “Pre-Chill” Bu on
3-5
Set Bu on
•
View Set Point
1
•
Change Set Point
3-5
•
SET + Down = CPSM
3-5
•
Reset Hi & Lo Bu on
3-5
ALARM
Pre-Chill Display
Control “ON/OFF” Bu on
•
Turns the Evaporator Unit
(Fan Coil Unit) “ON/OFF”
1
Compressor
Energ
Hi
Temp History &
Scroll Bu on
1
Low
Temp History &
Scroll Bu on
1
Energy Reduc on
Bu on
1
PLATINUM MINI-SPLIT SPECIFICATIONS
Model
Mini Evaporator Unit
(Fan Coil Unit)
Mini Condenser
Cellar Size (cu. ft.)
500
Dimensions
20”w x 10.5”h x 11.25”d 11.5”w x 9.9”h x 16”d
BTUh with 90° air entering
the condenser coil.
1540
CFM
94
190
Refrigerant
R-134a
Condensing Unit HP
1/5
Voltage Rating
(20 amp
dedicated circuit required)
115V or 230V - 20 amp dedicated circuit required
Weight (lbs)
25
41
AMPS
(Starting/Running)
2/1
11/3.8
dBA
51
65
Line Set
Suction Line 3/8” od. Liquid Line 1/4” od
Drainline
1/2”
Installation
Evaporator Unit (Fan Coil Unit) is installed in the cellar. The Condensing Unit is installed up to 100
Thermostat
Digital Control Display
Temp. Delta
(maintains proper cellar temperature when exhaust environment does not exceed 110°F)
Warranty
2 year parts and labor