Drain Line
All systems come with a drain line for additional removal of excessive condensate. It is mandatory to install the
drain line whether it leads through the wall and out of the cellar or remains inside the cellar. During operation, the
cooling system will strip excess water from the air in order to maintain the proper level of humidity within the cellar.
However in extreme humidity, additional condensate will be removed. Thus the drain line will prevent overflow and
leaking by allowing for discharge of the additional condensate.
Failure to install the drain line
voids the warranty.
To prevent mold from growing,
allow the drain line to hang
above the water line.
Condensation Drain Line
The condensation drain line tube is used to remove excess condensation from the Evaporator Unit ( Fan Coil Unit) to a
proper discharge location. It is important that the drain line tube is properly connected and used to prevent leakage
and other problems associated with excess condensation.
Failure to use the condensation drain line tube will void the warranty on the unit.
WRONG:
Drain line is under water.
INSTALLING THE EVAPORATOR UNIT (FAN COIL UNIT): DRAIN LINE
Insert the middle barb of the barbed tee
fitting into to the end of the drain line
coming from the evaporator. Rotate fitting
so tee is in the orientation shown in the
diagram on the left. Connect the three inch
piece to the barb on top. Connect the
remaining “long” piece of drain tubing to
the bottom barb of the tee.
NOTE:
The fitting should be placed vertical
with the three inch cut out facing up.
NOTE:
The fitting should be
placed vertical with the three
inch cut out facing up.
THROUGH THE WALL DRAIN LINE
OPTION 1
INSIDE CELLAR DRAIN LINE
OPTION 2
°
F
3”
CELLAR WALL
WALL MOUNT CLAMP