4-22
REMOVING THE FC THERMISTOR, AND THE CAVITY
THERMOSTAT & HUMIDITY SENSOR
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug microwave oven or disconnect
power.
2. Remove the microwave oven from its
mounting location (see page 4-17 for the
procedure).
3. Remove the cabinet from the microwave
oven (see page 4-18 for the procedure).
4. Peel back the foil from the rear of the top
cover.
5. Remove the six indicated T10 torx screws
from the top cover.
6. Lift the top cover by the bracket and re-
move the cover from the microwave oven.
7.
To remove the FC thermistor:
a) Squeeze the ends of the clip and re-
move the clip and the FC thermistor.
b) Remove the FC thermistor wires from
the standoffs at the top of the chassis.
FC Thermistor
FC Thermistor Clip
Wire Standoff
c) Disconnect the FC thermistor connec-
tor at relay control board plug P71,
and remove the thermistor.
FC Thermistor
Connector P71
Cavity Thermostat
& Humidity Sensor
6 Top Cover Screws
Summary of Contents for SPEEDCOOK GH6208 XR