2-9
EXPLOSION HAZARD
Use a new AGA or CSA approved gas
supply line.
Install a shutoff valve.
Securely tighten all gas connections.
If connected to L.P. gas, have a qualified
person make sure gas pressure does not
exceed 13
″″″″″
(33 cm) water column.
Examples of a qualified person include:
Licensed heating personnel.
Authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explo-
sion, or fire.
WARNING
GAS SUPPLY REQUIREMENTS
GAS TYPE
Natural Gas:
This dryer is equipped for use with NATURAL
GAS. It is design-certified by CSA International
for L.P. (propane or butane) gases with appro-
priate conversion.
• Your dryer must have the correct burner for
the type of gas in your home. Burner infor-
mation is located on the rating plate in the
door well of your dryer. If this information
does not agree with the type of gas available,
contact your local Whirlpool Service Center.
L.P. Gas Conversion:
Conversion must be made by a qualified
technician.
No attempt shall be made to convert the appli-
ance from the gas specified on the model/serial
rating plate for use with a different gas without
consulting the serving gas supplier.