25
At the end of the Built-in Test it is possible to reset to “0” the Water Filter Indicator and/or
Antibacterial Filter Indicator in the following way:
-
Water Filter Indicator Factory/Service reset
Press 4 times consecutively (within 10 sec) the Water valve shaft switch.
The symbol “F” on the Refrigerator display shall be shown in order to confirm the operation.
-
Antibacterial Filter Indicator Factory/Service reset
Press 4 times consecutively (within 10 sec) the Refrigerator Compartment door switch.
The symbol “A” on the Refrigerator display shall be shown in order to confirm the operation.
Built-In Test check code (User Interface operation)
The check code will be displayed on the Fridge display. Every check will have the related check
code that will be the same as the sequence number foreseen during the Built-in Test.
ERROR TYPE
ERROR
CODE
NOTE
Components (Relay Damper)
8
Displayed on 1 digit Fridge display
Evaporator De-Frost heater
7
Displayed on 1 digit Fridge display
Fridge probe
6
Displayed on 1 digit Fridge display
Freezer probe
5
Displayed on 1 digit Fridge display
Evaporator fan
4
Displayed on 1 digit Fridge display
Compressor fan
3
Displayed on 1 digit Fridge display
Damper
2
Displayed on 1 digit Fridge display
Water valve dispenser
1
Displayed on 1 digit Fridge display
Ice valve
9
Displayed on 1 digit Fridge display
Ice Maker Sankyo
H
Displayed on 1 digit Fridge display
OPERATION TYPE
OPERATION
CONFIRMED
CODE
NOTE
Water Filter Indication reset
by Service/Factory
F
Displayed on 1 digit Fridge display
Antibacterial Filter Indication
reset by Service/Factory
A
Displayed on 1 digit Fridge display
If 2 or more errors code have been recognized these codes shall be displayed on fridge
display in a rolling way (each code will persist about 1 second till the Built-in Test will be