17
3-
MRC II Fault Code Procedure (continued)
All F1 E* Codes (Control)
F2 Fault Code (Stuck Key on Control)
F3 E0 (Upper Oven Sensor), F3 E1 (Lower Oven Sensor)
Run Diagnostic Mode and verify
•
fault Code
•
Unplug range or disconnect power
•
Replace Control
•
Run Diagnostic Mode and verify
•
fault code
Unplug range or disconnect power
•
If fault code was F3 E0 - Check
•
upper oven sensor for 1000-1200Ω
at P10-3 to P10-4
If fault code was F3 E1 - Check
•
Lower Oven Sensor for 1000-1200 Ω
at P10-1 to P10-2
Check Sensor for short to ground.
•
If checks are not correct - Replace
•
Sensor
Run Diagnostic Mode and verify
•
fault Code
Run Keyboard test
•
Unplug range or disconnect
•
power
If keyboard test fails -
•
Replace User Interface
If keyboard test is successful -
•
Replace Control