Wiring Information
TS# W10200950
NOTE:
Schematic shows doors closed and relays off
3
Wiring Diagrams
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
L1
BK
BK
G
COOKTOP TO
MAINBACK
GND
OVEN CONTROL LCC90
OVEN LIGHT RELAY (K-2)
CON1-5
V
V
CON 3-9
CON 3-10
CON 3-3
CON 3-4
CON 1-1
POWER
SUPPLY
BAKE AND BROIL RELAY (K-6)
CON 2-1
R
Y
Y
W
OVEN TEMP
SENSOR
BK
SURFACE BURNER
IGNITION SWITCHES
R
SPARK MODULE
GND
R
BAKE IGNITER
BAKE VALVE
W
OPTIONAL
W
W
W
W
N
OVEN LIGHT
BK
CON 2-4
BK
R
COMPONENT
TERMINAL
CONNECTION
(SPLICE)
NO
CONNECTION
ON
SOME
MODELS
IN LINE
CONNECTION
LEGEND
Connectors
2
Failure/Error Display Codes
Quick Connect Plugs
DISPLAY
CODES
LIKELY FAILURE CONDITION
SUGGESTED CORRECTIVE ACTION PROCEDURE
CLr
No error(s) found
(Good) No corrective action required
F1
Control failure
UL A/D Error(s)
BAKE/BROIL range over temperature
1. Verify failure, if not displayed. Go to the diagnostics screen and clear the error code by
pressing the START key.
2. Unplug range or disconnect power longer than 30 seconds.
3. Plug in range or reconnect power.
4. Observe for longer than 1 minute.
5. If failure remains, go to Step 6.
6. Unplug range or disconnect power.
7. Replace control.
8. Replace all parts and panels before operating.
9. Plug in range or reconnect power.
10. Verify operation is normal. Go to Step 1 and complete checks.
F2
Shorted key
1. Verify failure, if not displayed. Go to the diagnostics screen and clear the error code by
pressing the START key.
2. Unplug range or disconnect power longer than 30 seconds.
3. Plug in range or reconnect power.
4. Observe for longer than 1 minute.
5. If failure remains, go to Step 6.
6. Unplug range or disconnect power.
7. Replace control.
8. Replace all parts and panels before operating.
9. Plug in range or reconnect power.
10. Verify operation is normal. Go to Step 1 and complete checks.
F3
Oven sensor opened
Oven sensor shorted
1. Unplug range or disconnect power.
2. Disconnect sensor from harness.
3. Measure sensor value (between connector pins) between 1000
Ω
@ 32°F (0°C) and
2697
Ω
@ 900°F (482.2°C) (room temperature approximately = 1080
Ω) .
Also measure
from sensor connector to sensor casing for possible short. If measurement does not
correlate to real temperature, or if short is found, replace sensor.
4. Trace wires and connectors to sensor from control, then back to control. If wire or
connection is damaged, replace the harness.
5. Reconnect the sensor to the harness.
6. Replace all parts and panels before operating.
7. Plug in range or reconnect power.
8. Press BAKE and START. Observe for longer than 1 minute. If failure remains,
go to Step 9.
9. Unplug range or disconnect power.
10. Replace control.
11. Replace all parts and panels before operating.
12. Plug in range or reconnect power.
13. Verify operation is normal. Go to Step 1 and complete checks.
CON 1
1
W
BK
CON 3
1
R
BK
Y
Y
V
V
CON 2
1
Summary of Contents for AER5522VAS0
Page 10: ...1 1 NOTES ...
Page 14: ...5 1 NOTES ...
Page 26: ...17 1 NOTES ...
Page 32: ...23 1 NOTES ...
Page 38: ...1 2 NOTES ...
Page 42: ...5 2 NOTES ...
Page 51: ...1 3 Notes ...
Page 63: ...13 3 Notes ...
Page 70: ......