11
2-
All F1 E* Codes (Control)
F2 Fault Code (Stuck Key on Control)
F3 E0 (Sensor)
Run Diagnostic Mode and
•
go to "Faults" display
Verify fault code
•
Unplug range or disconnect
•
power.
•
Replace Control
•
Run Diagnostic Mode and go
•
to “Faults” display
Verify fault code
•
Unplug range or disconnect
•
power.
Check Ribbon Connector on
•
Control
If connector is good
•
Replace Control
Run Diagnostic Mode and go
•
to “Faults” display
Verify fault code
•
Unplug range or disconnect
•
power.
Check Sensor for 1000-1200
•
Ω
at P10-1 to P10-2
Check Sensor for short to
•
ground
If checks are not correct -
•
Replace Sensor
F3 E2 (Warming Drawer Sensor)
MRC Fault Code Procedure (continued)
Run Diagnostic Mode and go
•
to “Faults” display
Verify fault code
•
Unplug range or disconnect
•
power.
Check Sensor for 1000-1200 Ω
•
at P10-3 to P10-4
Check Sensor for short to
•
ground
If checks are not correct -
•
Replace Sensor