6
2-
Reviewed by Staples, Debra L. | Released
MRC Control, Convection, Gas
MRC Convection, Gas
GFG461LVB0
GFG461LVB1
GFG461LVB2
GFG461LVQ0
GFG461LVQ1
GFG461LVQ2
GFG461LVS0
GFG461LVS1
GFG461LVS2
GFG461LVT0
GFG461LVT1
GFG461LVT2
GFG464LVB0
GFG464LVB1
GFG464LVQ0
GFG464LVQ1
GFG464LVS0
GFG464LVS1
Models:
Models:
MRC Control, Convection, Warming Drawer, Gas
Reviewed by Staples, Debra L. | Released
GFG471LVB0
GFG471LVB1
GFG471LVQ0
GFG471LVQ1
GFG471LVS0
GFG471LVS1
Previous Offset shown, or U-00 is displayed.
Adjusts temperature in 5
⁰F (3⁰C) increments
between -30⁰F (-18⁰C) and +30⁰F (+18⁰C).
Bake and Broil Temperatures are offset
automatically to the same degree.
If
START is not pressed within 1 minute,
adjustment is ignored.
Display
"TEST ON" ##⁰F "UO" (In the test mode)
"USAGE" (Displays hours of Operation)
"ENG MODE" (Manufacturing Information)
"TEST MODE" (Manual check of Control relays)
"VERSION" (Manufacturing Information)
"DISPLAY" (Checks all LEDs in Display)
"CONTROL RESET" (Resets Control settings)
"FAULTS" *(Displays all Fault Codes)
"AUTO TEST" (Performs a complete check of
the OVEN, automatically)
When checking for fault codes and "NO FAULTS" is displayed, do not change the control.
"+" again
"+" again
Diagnostic Mode
1. Press CANCEL/CANCEL/START
2. Press the TEMP/TIME "+" key
Action
Press "+" again
"+" again
"+" again
"+" again
The "AUTO TEST" program will automatically test all the oven circuits. This test is very easy
to use and when the test is complete, test results will be provided. Whenever servicing the
oven, this is the test to run.
When in the Diagnostic mode, instructions will be provided by the control to help you
through each of the programs. Press Cancel to exit the test at any time.
*Press Start Time to clear all fault codes
Temperature Adjustment
2. Press TEMP/TIME "+" or "-".
1. Press "BAKE" for 5 seconds.
3. Press START.
"+" again
Previous Offset shown, or U-00 is displayed.
Adjusts temperature in 5
⁰F (3⁰C) increments
between -30⁰F (-18⁰C) and +30⁰F (+18⁰C).
Bake and Broil Temperatures are offset
automatically to the same degree.
If
START is not pressed within 1 minute,
adjustment is ignored.
Display
"TEST ON" ##⁰F "UO" (In the test mode)
"USAGE" (Displays hours of Operation)
"ENG MODE" (Manufacturing Information)
"TEST MODE" (Manual check of Control relays)
"VERSION" (Manufacturing Information)
"DISPLAY" (Checks all LEDs in Display)
"CONTROL RESET" (Resets Control settings)
"FAULTS" *(Displays all Fault Codes)
"AUTO TEST" (Performs a complete check of
the OVEN, automatically)
When checking for fault codes and "NO FAULTS" is displayed, do not change the control.
"+" again
"+" again
Diagnostic Mode
1. Press CANCEL/CANCEL/START
2. Press the TEMP/TIME "+" key
Action
Press "+" again
"+" again
"+" again
"+" again
The "AUTO TEST" program will automatically test all the oven circuits. This test is very easy
to use and when the test is complete, test results will be provided. Whenever servicing the
oven, this is the test to run.
When in the Diagnostic mode, instructions will be provided by the control to help you
through each of the programs. Press Cancel to exit the test at any time.
*Press Start Time to clear all fault codes
Temperature Adjustment
2. Press TEMP/TIME "+" or "-".
1. Press "BAKE" for 5 seconds.
3. Press START.
"+" again
*Press “START TIME” to clear all fault codes