EASY 6000
– Issue 02
19
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI)
– tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: [email protected]
E
N
G
L
I
S
H
MULTIPRICE
If command 58 is set at 2 (2 prices for each drum) or 3 (3 prices for each drum) the machine
works by price line and therefore the programming procedure is the following:
For example, proceed as follows if you want to display the number of sales made at price 19 (products
contained in section 3 of drum 3):
1 Programming mode, the display will show Command 00
2 Enter 7 and press ENTER, the display will show Price number 00
3 Enter 19 and press ENTER, the display will show the desired value Number sales 0000
4 Press ENTER, the display will show Price number 00
Command 08 Display sales per discounted price selection:
This is like command 07 but you enter the submenu for displaying sales at the discounted price.
Command 09 Displays totals cashed not clearable:
Use this command to display the totals regarding the transactions carried out from the initialization of the
machine. The available data are the following:
Total sold, tot. in counter, tot. in tubes, tot. banknotes, tot. given back, tot. given out manually by the tubes,
tot. cashed overprice, tot. discounted sales, tot. sales with system cash less, tot. sold with exact amount, tot.
cashed without sales, number of sales carried out, total value of the free vends, total number of the free
vends.
Command 10 Displays totals clearable:
This command has the same functions as command 09, but it can be cleared through command 92.
8.2.2
SETTING THE TEMPERATURE PARAMETERS
Command 41 Sets cabinet temperature:
This command sets the lower internal cabinet temperature of the machine, i.e. the temperature below which
the compressor is turned off. The preset value is +3°C. This value can be varied b2 ÷ +25°C.
Command 43 End defrosting temperature setting:
Every time the compressor pauses, the temperature of the evaporator is controlled by the evaporator feeler.
This command allows the evaporator temperature to be set, above which, after dripping, the compressor can
restart operating; this is to ensure complete defrosting of the evaporator itself. The command is preset at 3°C
and can vary between 3°C and 12°C.
Command 44 Sets defrost cycle frequency:
This command sets the interval between defrost cycles expressed in hours. This value can be varied from 1h
and 8h and is preset at 4h.
Command 45 Setting the cut-out duration for the refrigeration safety device:
This command sets the amount of time that the refrigeration safety device is to remain disabled. This period
of time prevents the vending machine from shutting down following an operation that involves having the door
open with the subsequent increase in the internal temperature. The delay in activating the refrigeration unit
safety device gives the machine time to return to its normal operating temperature. The value of this
command is preset at 60 min. but can be varied from 30 to 360 min.
Summary of Contents for Easy 6000