Command 99 View error events:
This command displays the last 20 error events; to go from one display to another press the ENTER key. At
the end of the display, the system asks the user to confirm the clearing of all the data. Press ENTER to
confirm or ESC to leave the records as they are.
ERROR CODE
SUB-CODE
Meaning
01
Door no.
Door does not open during sale
02
Door no.
Door does not close (only Command 01 Machine test)
03
Drum no.
Column tries to rotate drum with door open
05
Drum no.
Drum position time out
07
Drum no.
Column does not reach zero position
08
Drum no.
No drum encoder pulses
10
/
Internal temperature probe defective
11
/
Evaporator probe defective
16
/
Communication with power board blocked
20
/
Delivery door not controllable
21
/
Incorrect position parameter
25
Door no.
Door does not open during reloading
26
Door no.
Door does not close during reloading
29
Drum no.
Power board reset or the drum control card
30
/
Fridge safety intervention
Summary of Contents for Easy 6000