10.7 INSTRUCTIONS FOR REPLACING THE INTERNAL LIGHTING DEVICE
Switch off the machine by means of the main switch and disconnect the plug.
Open the main door.
Remove the cover from the light source.
Replace the light source.
Carry out the operations in reverse order to reassemble.
10.8 ACCESS TO THE ELECTRICAL PANELS AND TO THE REFRIGERATION UNIT
Proceed as follows to access the electrical panels or refrigeration unit:
Turn off the machine by means of the main switch and pull out the plug.
Open the door.
Using a Phillips-head screwdriver, unscrew the screws which fix the product recovery pocket and the
moneybox pocket to the machine structure. Remove the pockets.
To remove the refrigeration unit, lower the two levers at the sides of the evaporator box, make sure that
gasket located in the top edge of the evaporator box is completely detached from its sealing seat, and
pull the provided handle. ATTENTION to the wiring.
Electric panel
: When the product collection pocket is removed the entire vending
machine remains energised. To disconnect the power remove the red key inserted in the
terminal board. Total isolation from the electric power supply is only obtained when the
plug is removed from the external magnetothermal switch. Consequently, all operations
required by the vending machine without the protection of the product collection pocket,
must only be carried out by qualified personnel who are aware of the specific hazards
which this condition involves.