I
NSTALLATION
S
ET
-U
P
Table 5: Minimum ‘H’ for Figure 44.
Roof Pitch
Minimum Height (H)
Feet
Meters
Flat to 7/12
1
0.3
Over 7/12 to 8/12
1.5
0.46
Over 8/12 to 9/12
2
0.61
Over 9/12 to 10/12
2.5
0.76
Over 10/12 to 11/12
3.25
0.99
Over 11/12 to 12/12
4
1.22
Over 12/12 to 14/12
5
1.52
Over 14/12 to 16/12
6
1.83
Over 16/12 to 18/12
7
2.13
Over 18/12 to 20/12
7.5
2.29
Over 20/12 to 21/12
8
2.44
Figure 44: Height of Vertical Termination;
Reference Table 5.
D
OOR
R
EMOVAL
AND
I
NSTALLATION
:
1) The fireplace door is hung on two (2) hooks on the top of the
firebox. The two (2) door latches at the bottom of the firebox
hook over the tabs on the bottom of the door frame.
2) Lower the door latch tool underneath the door frame. Catch
the lower door latch with the door latch tool (see Figure
45) and pull it out slightly, then down. Once the lower door
latch clears the tab on the bottom of the door frame, release
it inwards and then remove the door latch tool. Refer to
Figures 47 & 48.
3) Pull the Door Frame at the bottom forward about 2” (5cm),
then lift the Door Frame upwards to clear the Upper Door
Hooks. Refer to Figures 48 & 49.
Figure 45: Door Latch /Air Adjustment Tool.
Figure 47: Door Latch Tool in Place.
Figure 46: Door Latch Locations.