Programming
24
The display shows
P7
.
The unit is in the mode “Max. Motor RunTime for gate opener
1
”.
Attention!
The motor run time is to protect the motor from damage in case of
malfunction or improper adjustment.
The default setting for the motor run time is 40 seconds. This will
protect the motor from an endless run and damage if the EMER-
GENCY Release is not locked in place or if there is any kind of
malfunction. In this case the motor will automatically stop turning
after 40 seconds.
Normally the motor needs less than 30 seconds in order to retract
the fully extended moving rod (385 mm). If the limit switch B is
positioned correctly, the EMERGENCY Release is locked in place
and the run time (see setting mode PC) for the gate opener is
adjusted correctly, the motor run time will not take effect as the
motor will stop shortly before.
If desired you can shorten the motor run time.
P7 Max. Motor Run Time for Gate Opener 1
1. Press INC or DEC.
Factory setting = 40 sec. Settings from 0
– 40 sec. are possible.
2. For storing press FUNC.
The display shows
P8
.
The unit is in the mode “Max. Motor Run Time for gate opener
2”.
P8 Max. Motor Run Time for Gate Opener 2
Same procedure as P7 Max. Motor Run Time for Gate Opener
1. The display shows
P9
.
The unit is in the mode “Photocell Beam System” (not availa-
ble).