Programming
20
Before programming the opener make sure the moving rod/s
is/are extended!
EMERGENCY Release before Programming
1. Releasing the motor and pull out the moving
rod by using the triangular key.
2. Lock the motor after pulling out the moving
rod (turning counter clockwise).
P1 Programming single Gate Opener
1. As soon as the control box is connected to power mains, the
display starts flashing and shows
“
– –
“. Now the unit is in
standby mode.
2. Hold the button FUNC pressed for more
than 4 seconds.
The display shows
P1
.
The unit is in setting mode for operating
1 resp. 2 gate openers.
3. Press the button DEC to start the settings.
INC = Increase
DEC = Decrease
01
= gate opener 1
10
= gate opener 2
11
= Dual gate opener mode
Gate opener 1 is mounted on the right side of the gate and the
gate opener 2 is mounted on the left side of the gate.
4. For storing press FUNC.
The display shows
P2
.
}