Programming
26
PC Setting the Fast Run Time and Soft Stop Time
While adjusting the Fast Run Time, the Soft Stop Function will be
achieved simultaneously. Soft Stop Function means that the gate
opener runs at slow speed during the last period before the gate
completely opens or closes. The Soft Stop Time cannot be directly
adjusted. It can only be determined by adjusting the Fast Run Time.
That means: To reduce the Soft Stop Time, the Fast Run Time has
to be extended.
Soft Start Time
+
Fast Run Time
+
Soft Stop Time
=
Total Run Time
Fast Run Time
=
Total Run Time
–
Soft Start Time
–
Soft Stop Time
15 seconds
=
30 seconds
–
3 seconds
–
12 seconds
When the Soft Start Time is set at 3 seconds (under mode Pb) and
the Total Run Time is 30 seconds, the Fast Run Time has to be
adjusted to 15 seconds in order to meet the Soft Stop Time of 12
seconds.
Adjust in the
Menu
Pb
3 sec.
Adjust in the
Menu
PC
15 sec.
This will result to
a Soft Stop
Time of 12 sec.
This will result to
a Total Run
Time of 30 sec.
The values (3 seconds for soft start time and 15 seconds for run
time) are the default setting values. These values can be changed
accordingly.
1. Press INC or DEC.
Default setting for the run time = 15 sec. Settings from 1
– 28
are possible.
2. For storing press FUNC.
The display shows
Pd
.
3. Press the button FUNC once more in order to quit the menu and
to save the setting.
The display shows “
– –
“.