Programming
22
1
2
2. For storing press FUNC.
The display shows
P3
.
The unit is now in the mode “Master/Slave Open Interval”.
P3 Setting the Master/Slave Open Interval
1. Press INC or DEC.
00
= Master gate and Slave gate open simultaneously.
01
= Master gate will open 1 second before the Slave gate.
02
= Master gate will open 2 seconds before the Slave gate.
03
= Master gate will open 3 seconds before the Slave gate, etc.
Factory setting is 3 sec. Max. 9 seconds are adjustable.
2. For storing press FUNC.
The display shows
P4
.
The unit is now in the mode
“Master/Slave Close Interval”.
P4 Setting the Master/Slave Close Interval
1. Press INC or DEC.
0
= Master gate and Slave gate will close simultaneously.
1
= Master gate will close 1 second after the Slave gate.
2
= Master gate will close 2 seconds after the Slave gate, etc.
Factory setting is 3 sec. Max. 9 seconds are adjustable.
2. For storing press FUNC.
The display shows
P5
.
The unit is now in the mode “Blocking Force for gate opener 1”.