27
INDICATOR & BASESTATION
1. Connect the BaseStation to scale indicator (or other appropriate device)
using the serial interface cable provided. Interface cables are Beldon
Type 8723. See table for pin outs:
INDICATOR
9 PIN (MALE) CONNECTOR
TRANSMIT (TX)
PIN 3
RECEIVE (RX)
PIN 2
SIGNAL GROUND (GND)
PIN 5 (GND)
2. The indicator should be set to output
CONTINUOUSLY
in the following
format (RS 232):
Baud Rate
9600
Parity
None
Data Bits
8
Stop Bits
1
3. Apply power to BaseStation using the 12 V power supply provided.
The unit should now be transmitting the indicator’s output string.
Wireless Connection Test
1. Add weight to the scale.
2. Verify that the Aurora is correctly displaying Weight, Measurement Units
(kg, lb), and Weighing Mode (GR, NT) as shown on the scale indicator.
3. If the Aurora’s readings are incorrect, erratic, or very slow, a different radio
channel may need to be selected.
NOTE: If the indicator cannot be set as above, the BaseStation